EP01.59: AI‐driven follicle measurement: evaluation of SonoAVCTM follicle auto caliper

Assessing the number and size of follicles is an essential step during fertility treatments. Measuring follicular size during stimulation is of particular importance as it provides an indication of oocyte maturity. However, such measurements are time-consuming and prone to intra- and interobserver variability, therefore warranting the development of automated techniques. SonoAVC™ follicle Auto Caliper (GE HealthCare, Zipf, Austria) is a novel semi-automated tool that places two-dimensional (2D) calipers on follicles based on user interaction, namely tap or click. This study is aimed to assess its performance on retrospective data. The semi-automatic caliper placement was developed based on the segmentation outputs of a deep neural network. The tool places 2 orthogonal calipers onto user-selected follicles. Ground truth (GT) annotations for training and validation were contoured by junior medical professionals and reviewed by a senior obstetrics and gynecology practitioner. The offline evaluation of the SonoAVC™ follicle Auto Caliper tool was performed in an inhouse developed tool on 14 volumes. Manual 2D calipers were placed by a senior and junior medical staff. Follicle count measurements were performed during postprocessing. Bland-Altman plot analysis revealed smaller limits of agreement between the calipers placed on the automatic predictions and GT annotations on operator selected slice (senior: 0.92 and –1.22; and novice: 1.19 and –1.35) than between the senior and GT (1.35 and –1.24); and junior and GT (1.34 and –1.52). The tool's performance is comparable to the operators in terms of follicle counts. The evaluation indicates that users employing SonoAVC™ follicle Auto Caliper reached a better or similar performance, than users placing the calipers manually. SonoAVC™ follicle Auto Caliper accelerates the clinical workflow by reducing the keystroke amount from four clicks/taps to one.

Authors

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28073
Primary Topic
Reproductive Biology and Fertility
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP01.59: AI‐driven follicle measurement: evaluation of SonoAVCTM follicle auto caliper

Martin P. Mienkina, Marcus Hofbauer, Apoorva Gogna, Frank J. Schwab et al.
2 links
Ultrasound in Obstetrics and Gynecology
Reproductive Biology and Fertility
article

EP01.59: AI‐driven follicle measurement: evaluation of SonoAVCTM follicle auto caliper

Martin P. Mienkina, Marcus Hofbauer, Apoorva Gogna, Frank J. Schwab, V. Czipczer, Edina Timkó, Mária Prosszer, A. Olajos‐Horváth, N. Kéri, D. Várkonyi
article en

Abstract

Assessing the number and size of follicles is an essential step during fertility treatments. Measuring follicular size during stimulation is of particular importance as it provides an indication of oocyte maturity. However, such measurements are time-consuming and prone to intra- and interobserver variability, therefore warranting the development of automated techniques. SonoAVC™ follicle Auto Caliper (GE HealthCare, Zipf, Austria) is a novel semi-automated tool that places two-dimensional (2D) calipers on follicles based on user interaction, namely tap or click. This study is aimed to assess its performance on retrospective data. The semi-automatic caliper placement was developed based on the segmentation outputs of a deep neural network. The tool places 2 orthogonal calipers onto user-selected follicles. Ground truth (GT) annotations for training and validation were contoured by junior medical professionals and reviewed by a senior obstetrics and gynecology practitioner. The offline evaluation of the SonoAVC™ follicle Auto Caliper tool was performed in an inhouse developed tool on 14 volumes. Manual 2D calipers were placed by a senior and junior medical staff. Follicle count measurements were performed during postprocessing. Bland-Altman plot analysis revealed smaller limits of agreement between the calipers placed on the automatic predictions and GT annotations on operator selected slice (senior: 0.92 and –1.22; and novice: 1.19 and –1.35) than between the senior and GT (1.35 and –1.24); and junior and GT (1.34 and –1.52). The tool's performance is comparable to the operators in terms of follicle counts. The evaluation indicates that users employing SonoAVC™ follicle Auto Caliper reached a better or similar performance, than users placing the calipers manually. SonoAVC™ follicle Auto Caliper accelerates the clinical workflow by reducing the keystroke amount from four clicks/taps to one.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
Openalex Percentile: Top 77%
Reproductive Biology and Fertility
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.