EP01.54: Placenta functional study with BOLD MRI: random biopsies versus whole‐placenta analysis

Functional MRI has been identified as potential tool to study the placental function in-vivo. However, the offline processing of these data is time-consuming, particularly when it comes to manual segmentation. We compared the whole-placenta analysis to random samples with different placental volumes. We performed a BOLD MRI acquisition in normoxia, followed by a period of oxygen supply until placental oxygen saturation in a cohort of normal pregnancies. After a non-rigid registration to correct motion artifacts, a whole-placenta mask was manually segmented. Thereafter, three random samples were automatically generated within the whole-placenta mask, mimicking random biopsies and covering 10%, 30% and 50% of the placental area. The signal change over time was modelled using a sigmoid function, from which the intensity of enhancement () and a temporal variation coefficient (min-1, controlling the slope of the curve) were deduced. The parameters from the random samples were compared to the whole-placenta parameters. The mean differences in between the whole placenta and the random samples were 20.08%, 8.29% and 5.15% for the 10%, 30% and 50%-random masks, respectively. Subsequently, the ICCs were 0.91 [0.8, 0.96], 0.99 [0.97, 1] and 0.99 [0.99, 1] for the 10%, 30% and 50%-random masks, respectively. Similarly, the mean differences in (min-1) between the whole placenta and the random samples were 32.13%, 10.25% and 7.71% for the 10%, 30% and 50%-random masks, respectively. The ICCs were 0.02 [-0.41, 0.45], 0.96 [0.91, 0.99] and 0.95 [0.88, 0.98] for the 10%, 30% and 50%-random masks, respectively. In addition, the fitting failed in 3 cases for the 10%-mask, 2 cases for the 30%-mask and 1 case for the 50% mask, requiring new random samples. Our results suggest that small random placenta samples do not reflect the functional parameters with precision, illustrating the presence of functional variations within the placenta.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2024-09-01
DOI
https://doi.org/10.1002/uog.28068
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EP01.54: Placenta functional study with BOLD MRI: random biopsies versus whole‐placenta analysis

Andrew Melbourne, D. Grévent, Raphaël Bartin, Laurent Salomon
Ultrasound in Obstetrics and Gynecology
Pregnancy and preeclampsia studies
article

EP01.54: Placenta functional study with BOLD MRI: random biopsies versus whole‐placenta analysis

Andrew Melbourne, D. Grévent, Raphaël Bartin, Laurent Salomon
article en

Abstract

Functional MRI has been identified as potential tool to study the placental function in-vivo. However, the offline processing of these data is time-consuming, particularly when it comes to manual segmentation. We compared the whole-placenta analysis to random samples with different placental volumes. We performed a BOLD MRI acquisition in normoxia, followed by a period of oxygen supply until placental oxygen saturation in a cohort of normal pregnancies. After a non-rigid registration to correct motion artifacts, a whole-placenta mask was manually segmented. Thereafter, three random samples were automatically generated within the whole-placenta mask, mimicking random biopsies and covering 10%, 30% and 50% of the placental area. The signal change over time was modelled using a sigmoid function, from which the intensity of enhancement () and a temporal variation coefficient (min-1, controlling the slope of the curve) were deduced. The parameters from the random samples were compared to the whole-placenta parameters. The mean differences in between the whole placenta and the random samples were 20.08%, 8.29% and 5.15% for the 10%, 30% and 50%-random masks, respectively. Subsequently, the ICCs were 0.91 [0.8, 0.96], 0.99 [0.97, 1] and 0.99 [0.99, 1] for the 10%, 30% and 50%-random masks, respectively. Similarly, the mean differences in (min-1) between the whole placenta and the random samples were 32.13%, 10.25% and 7.71% for the 10%, 30% and 50%-random masks, respectively. The ICCs were 0.02 [-0.41, 0.45], 0.96 [0.91, 0.99] and 0.95 [0.88, 0.98] for the 10%, 30% and 50%-random masks, respectively. In addition, the fitting failed in 3 cases for the 10%-mask, 2 cases for the 30%-mask and 1 case for the 50% mask, requiring new random samples. Our results suggest that small random placenta samples do not reflect the functional parameters with precision, illustrating the presence of functional variations within the placenta.

Ultrasound in Obstetrics and GynecologyVol. 64(S1)
Hôpital Necker-Enfants Malades (FR), King's College London (GB), Université Paris Cité (FR), Institut Necker Enfants Malades (FR)
Zero hunger
Openalex Percentile: Top 76%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.