EP19.20: Correlation between intrapartum derived levator ani muscle anteroposterior diameter are rest and during Valsalva with duration of labour
Prospective, quantitative cohort study that recruited 130 participants, 100 of the participants had vaginal delivery while 30 had Caesarean section. Consecutive sampling was done until the calculated sample size was reached. Transperineal imaging was done with the patient in a semirecumbent position and the images were obtained using 2D Logiq V2 General electric ultrasound machine. A digital exam was done to confirm the participant was in latent labour before. The levator ani muscle anteroposterior diameter had a negative correlation of -0.258 with duration of second stage with a significant P value of 0.01. Coactivation had no significant P value when an associated with duration of second stage was done. The P value was 0.330. Levator ani muscle diameter is has a strong predictive value when it comes to duration of second stage. This reflects what previous studies have found. Coactivation had an insignificant P value when an association with duration of second stage was done. P Value Coactivation
Authors
- Bob Achila
- Felix Mwembi Oindi (ORCID: https://orcid.org/0000-0002-4224-2599)
- Z.W. Sikolia
- M.M. Mwangi
Institutions
- Aga Khan University Hospital Nairobi (KE)
- Aga Khan University Nairobi (KE)
Publication Details
- Journal
- Ultrasound in Obstetrics and Gynecology
- Published
- 2024-09-01
- DOI
- https://doi.org/10.1002/uog.28803
- Primary Topic
- Health, Medicine and Society
- Type
- article
- Field-Weighted Citation Impact
- 0.00