Experimental study on fatigue damage mitigation in welded beam-to-column connections with passive vibration control

To investigate the effectiveness of a viscous fluid damper (VFD) in mitigating fatigue damage in welded beam-to-column connections, six specimens were manufactured with the full penetration groove weld process. These specimens were divided into three groups: S1, S2, and S3, each containing two specimens. One specimen in each group was equipped with VFD, while the other was not. All specimens underwent the same elastic cyclic loading stage, but a different plastic cyclic loading stage for each group. The study results indicate that the presence of VFD can significantly enhance the load-bearing capacity of the welded beam-to-column connection by 10%–15% when subjected to the same displacement amplitude at the beam end. The primary cause of failure in the welded beam-to-column connection is the fatigue damage of the weld toe on the beam flange, which requires more attention during the welding process. Additionally, the VFD can effectively reduce stress concentration at the weld seam area, leading to a maximum of 50% decrease in the maximum stress near the weld toe of the beam flange center, as observed in our study.

Authors

Institutions

Publication Details

Journal
Advances in Structural Engineering
Published
2024-09-09
DOI
https://doi.org/10.1177/13694332241281531
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on fatigue damage mitigation in welded beam-to-column connections with passive vibration control

Jianshao Zhang, Zhao Fang, Fan Yang, Aiqun Li
Advances in Structural Engineering
Structural Load-Bearing Analysis
article

Experimental study on fatigue damage mitigation in welded beam-to-column connections with passive vibration control

Jianshao Zhang, Zhao Fang, Fan Yang, Aiqun Li
article en

Abstract

To investigate the effectiveness of a viscous fluid damper (VFD) in mitigating fatigue damage in welded beam-to-column connections, six specimens were manufactured with the full penetration groove weld process. These specimens were divided into three groups: S1, S2, and S3, each containing two specimens. One specimen in each group was equipped with VFD, while the other was not. All specimens underwent the same elastic cyclic loading stage, but a different plastic cyclic loading stage for each group. The study results indicate that the presence of VFD can significantly enhance the load-bearing capacity of the welded beam-to-column connection by 10%–15% when subjected to the same displacement amplitude at the beam end. The primary cause of failure in the welded beam-to-column connection is the fatigue damage of the weld toe on the beam flange, which requires more attention during the welding process. Additionally, the VFD can effectively reduce stress concentration at the weld seam area, leading to a maximum of 50% decrease in the maximum stress near the weld toe of the beam flange center, as observed in our study.

Advances in Structural EngineeringVol. 28(2)
Nanjing Institute of Technology (CN), Guangzhou Design Institute (CN), Beijing University of Civil Engineering and Architecture (CN), Southeast University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 83%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.