Implementing and Evaluating the Timed Up and Go Test Automation Using Smartphones and Smartwatches

Physical performance tests aim to assess the physical abilities and mobility skills of individuals for various healthcare purposes. They are often driven by experts and usually performed at their practice, and therefore they are resource-intensive and time-demanding. For tests based on objective measurements (e.g., duration, repetitions), technology can be used to automate them, allowing the patients to perform the test themselves, more frequently and anywhere, while alleviating the expert from supervising the test. The well-known Timed Up and Go (TUG) test, typically used for mobility assessment, is an ideal candidate for automation, as inertial sensors (among others) can be deployed to detect the various movements constituting the test without expert supervision. To move from expert-led testing to self-administered testing, we present a mHealth system capable of automating the TUG test using a pocket-sized smartphone or a wrist smartwatch paired with a smartphone, where data from inertial sensors are used to detect the activities carried out by the patient while performing the test and compute their results in real time. All processing (i.e., data processing, machine learning-based activity inference, results calculation) takes place on the smartphone. The use of both devices to automate the TUG test was evaluated (w.r.t. accuracy, reliability and battery consumption) and mutually compared, and set off with a reference method, obtaining excellent Bland-Altman agreement results and Intraclass Correlation Coefficient reliability. Results also suggest that the smartwatch-based system performs better than the smartphone-based system.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2024-09-09
DOI
https://doi.org/10.1109/jbhi.2024.3456169
Citations
4
Primary Topic
Experimental Learning in Engineering
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementing and Evaluating the Timed Up and Go Test Automation Using Smartphones and Smartwatches

Alberto González‐Pérez, Sven Casteleyn, Carlos Granell, Miguel Matey-Sanz
4 citations
IEEE Journal of Biomedical and Health Informatics
Experimental Learning in Engineering
1.28
article

Implementing and Evaluating the Timed Up and Go Test Automation Using Smartphones and Smartwatches

Alberto González‐Pérez, Sven Casteleyn, Carlos Granell, Miguel Matey-Sanz
article en
4 citations

Abstract

Physical performance tests aim to assess the physical abilities and mobility skills of individuals for various healthcare purposes. They are often driven by experts and usually performed at their practice, and therefore they are resource-intensive and time-demanding. For tests based on objective measurements (e.g., duration, repetitions), technology can be used to automate them, allowing the patients to perform the test themselves, more frequently and anywhere, while alleviating the expert from supervising the test. The well-known Timed Up and Go (TUG) test, typically used for mobility assessment, is an ideal candidate for automation, as inertial sensors (among others) can be deployed to detect the various movements constituting the test without expert supervision. To move from expert-led testing to self-administered testing, we present a mHealth system capable of automating the TUG test using a pocket-sized smartphone or a wrist smartwatch paired with a smartphone, where data from inertial sensors are used to detect the activities carried out by the patient while performing the test and compute their results in real time. All processing (i.e., data processing, machine learning-based activity inference, results calculation) takes place on the smartphone. The use of both devices to automate the TUG test was evaluated (w.r.t. accuracy, reliability and battery consumption) and mutually compared, and set off with a reference method, obtaining excellent Bland-Altman agreement results and Intraclass Correlation Coefficient reliability. Results also suggest that the smartwatch-based system performs better than the smartphone-based system.

IEEE Journal of Biomedical and Health InformaticsVol. 28(11)
Universitat Jaume I (ES)
Openalex Percentile: Top 17%
Experimental Learning in Engineering
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.