Passivity-Based Controller Design of LCL-Filtered Selective-Harmonic Resistive-Active Power Filter

Passive property of grid-tied converter’s output admittance is widely recognized as favorable to stability. However, the admittance of active power filter (APF) is dependent on the nonlinear load (NLL) applied. Thus, the passivity-based design of APF is also dependent on the specific NLL. To deal with this problem, this article suggests replacing APF with resistive active power filter (RAPF) whose admittance is unrelated to NLL. Virtual impedance or virtual admittance control schemes are examined in this article. It turns out that none of them is stable. Then, a new control scheme is proposed which emulates desired virtual immittance at selected frequencies. Passivity-based controller design for proposed RAPF is then formulated. Meanwhile, a simpler calculation method for compensation angle of resonant controller is proposed. The effectiveness and correctness of the proposed control scheme is finally verified by experiments.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2024-09-09
DOI
https://doi.org/10.1109/tie.2024.3447755
Citations
4
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.68
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Passivity-Based Controller Design of LCL-Filtered Selective-Harmonic Resistive-Active Power Filter

Shan He, Ka Nang Leung, Poh Chiang Loh, Chao Gao et al.
4 citations
IEEE Transactions on Industrial Electronics
Power Systems and Renewable Energy
0.68
article

Passivity-Based Controller Design of LCL-Filtered Selective-Harmonic Resistive-Active Power Filter

Shan He, Ka Nang Leung, Poh Chiang Loh, Chao Gao, Rui Kong
article en
4 citations

Abstract

Passive property of grid-tied converter’s output admittance is widely recognized as favorable to stability. However, the admittance of active power filter (APF) is dependent on the nonlinear load (NLL) applied. Thus, the passivity-based design of APF is also dependent on the specific NLL. To deal with this problem, this article suggests replacing APF with resistive active power filter (RAPF) whose admittance is unrelated to NLL. Virtual impedance or virtual admittance control schemes are examined in this article. It turns out that none of them is stable. Then, a new control scheme is proposed which emulates desired virtual immittance at selected frequencies. Passivity-based controller design for proposed RAPF is then formulated. Meanwhile, a simpler calculation method for compensation angle of resonant controller is proposed. The effectiveness and correctness of the proposed control scheme is finally verified by experiments.

IEEE Transactions on Industrial ElectronicsVol. 72(4)
Chinese University of Hong Kong (HK), Aalborg University (DK)
Affordable and clean energy
Openalex Percentile: Top 26%
Power Systems and Renewable Energy
0.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Passivity-Based Controller Design of LCL-Filtered Selective-Harmonic Resistive-Active Power Filter — Shan He, Ka Nang Leung, et al. · IEEE Transactions on Industrial Electronics (2024) | TGRS Research Map | TGRS