A Silicon-Pixel Paradigm for PET

Positron emission tomography (PET) scanners use scintillation crystals to stop high-energy photons. The ensuing lower-energy photons are then detected via photomultipliers. We study the performance of a stack of monolithic silicon-pixel detectors as an alternative to the combination of crystals and photomultipliers. The resulting design allows for pitches as small as <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$100~ {\mu }$ </tex-math></inline-formula>m and greatly mitigates depth-of-interaction problems. We develop a theory to optimize the sensitivity of these and other scanners under design constraints. The insight is complemented by Monte Carlo simulations and reconstructions thereof. Experiments and theory alike suggest that our approach has the potential to move PET closer to the microscopic scale. The volumetric resolution is an order of magnitude better than that of the state of the art and the parallax error is very small. A small-animal scanner is now under construction.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2024-09-09
DOI
https://doi.org/10.1109/trpms.2024.3456241
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Silicon-Pixel Paradigm for PET

J. Saidi, Aleix Boquet-Pujadas, Michaël Unser, Pol del Aguila et al.
1 citations
IEEE Transactions on Radiation and Plasma Medical Sciences
Medical Imaging Techniques and Applications
0.40
article

A Silicon-Pixel Paradigm for PET

J. Saidi, Aleix Boquet-Pujadas, Michaël Unser, Pol del Aguila, Jonathan Dong, G. Iacobucci, L. Paolozzi, M. C. Vicente
article en
1 citations

Abstract

Positron emission tomography (PET) scanners use scintillation crystals to stop high-energy photons. The ensuing lower-energy photons are then detected via photomultipliers. We study the performance of a stack of monolithic silicon-pixel detectors as an alternative to the combination of crystals and photomultipliers. The resulting design allows for pitches as small as <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$100~ {\mu }$ </tex-math></inline-formula>m and greatly mitigates depth-of-interaction problems. We develop a theory to optimize the sensitivity of these and other scanners under design constraints. The insight is complemented by Monte Carlo simulations and reconstructions thereof. Experiments and theory alike suggest that our approach has the potential to move PET closer to the microscopic scale. The volumetric resolution is an order of magnitude better than that of the state of the art and the parallax error is very small. A small-animal scanner is now under construction.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(2)
University of Geneva (CH), Centre d'Imagerie BioMedicale (CH)
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Openalex Percentile: Top 35%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Silicon-Pixel Paradigm for PET — J. Saidi, Aleix Boquet-Pujadas, et al. · IEEE Transactions on Radiation and Plasma Medical Sciences (2024) | TGRS Research Map | TGRS