Ultrahigh-Sensitivity Detection of TNF-<i>α</i> Based on U-Shape Single Mode-Tapered Four Core-Single Mode Fiber Biosensor

In this article, a high-sensitivity U-shape single mode-tapered four core-single mode (STFS) optical fiber biosensor is proposed and investigated for tumor necrosis factor-alpha (TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula>) detection in both phosphate-buffered saline (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1\times $ </tex-math></inline-formula>) (PBS) and diluted serum. The surface of U-shape STFS biosensor is immobilized with TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> antibody (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10~\mu $ </tex-math></inline-formula>g/mL), which will specifically bind with target TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula>. The results demonstrate a Hill curve relationship between wavelength shift and TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> concentration (from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{{1}}$ </tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{{4}}$ </tex-math></inline-formula> pg/mL diluted in PBS). The lowest concentration of TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> detected in the experiment is 10 pg/mL, with an average wavelength shift of 0.389 nm. The average wavelength fluctuation of the sensor in PBS is 0.099 nm, and the corresponding limit of detection (LOD) is 4.35 pg/mL. Results for the detection of TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> in blood sample is also presented. It is found that the deviation of detected TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> concentrations (13.00–15.03 pg/mL, calibrated by measured results in PBS) is −0.7% to 14.7% compared to standard TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> concentration of 13.09 pg/mL in blood. This biosensor, with its simple structure and high sensitivity, has the potential to serve as a valuable reference in disease diagnosis and medical drug usage, offering promising application prospects.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-09-09
DOI
https://doi.org/10.1109/jsen.2024.3439630
Citations
4
Primary Topic
Advanced Biosensing Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrahigh-Sensitivity Detection of TNF-α Based on U-Shape Single Mode-Tapered Four Core-Single Mode Fiber Biosensor

Jinhui Yuan, Yue Fu, Wenbo Xiao, Dandan Wei et al.
4 citations
IEEE Sensors Journal
Advanced Biosensing Techniques and Applications
0.94
article

Ultrahigh-Sensitivity Detection of TNF-α Based on U-Shape Single Mode-Tapered Four Core-Single Mode Fiber Biosensor

Jinhui Yuan, Yue Fu, Wenbo Xiao, Dandan Wei, Bin Liu, Juan Liu, Qiang Wu, Xingdao He, Hao-Yuan Cao, Yingying Hu
article en
4 citations

Abstract

In this article, a high-sensitivity U-shape single mode-tapered four core-single mode (STFS) optical fiber biosensor is proposed and investigated for tumor necrosis factor-alpha (TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula>) detection in both phosphate-buffered saline (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1\times $ </tex-math></inline-formula>) (PBS) and diluted serum. The surface of U-shape STFS biosensor is immobilized with TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> antibody (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10~\mu $ </tex-math></inline-formula>g/mL), which will specifically bind with target TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula>. The results demonstrate a Hill curve relationship between wavelength shift and TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> concentration (from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{{1}}$ </tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10^{{4}}$ </tex-math></inline-formula> pg/mL diluted in PBS). The lowest concentration of TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> detected in the experiment is 10 pg/mL, with an average wavelength shift of 0.389 nm. The average wavelength fluctuation of the sensor in PBS is 0.099 nm, and the corresponding limit of detection (LOD) is 4.35 pg/mL. Results for the detection of TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> in blood sample is also presented. It is found that the deviation of detected TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> concentrations (13.00–15.03 pg/mL, calibrated by measured results in PBS) is −0.7% to 14.7% compared to standard TNF-<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\alpha $ </tex-math></inline-formula> concentration of 13.09 pg/mL in blood. This biosensor, with its simple structure and high sensitivity, has the potential to serve as a valuable reference in disease diagnosis and medical drug usage, offering promising application prospects.

IEEE Sensors JournalVol. 24(20)
Beijing University of Posts and Telecommunications (CN), Nanchang University (CN), First Affiliated Hospital of Nanchang University (CN), Nanchang Hangkong University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 25%
Advanced Biosensing Techniques and Applications
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.