Design of Miniaturized Sensing Unit for Underground Displacement 3-D Measurement Sensor

Existing underground displacement monitoring sensors require prior drilling, but the size of borehole will affect the workload of drilling. Meanwhile, the landslide monitoring site is often in the field where the traffic is inconvenient and vehicles cannot be directly reached, miniaturization can reduce the weight and volume of the sensor, making transportation and handling even more convenient. Therefore, miniaturization is carried out on the underground displacement 3-D measurement sensor based on double mutual inductance voltage contour method. This study has combined with COMSOL Multiphysics and actual testing, discussing the influence of the air-core coil parameters on sensitivity and measurement range of the sensor, optimizing the parameters of air-core coil inside sensing unit, improving the internal structure of sensing unit to increase the sensitivity of the sensor. Additionally, this study has designed the sensor for low power consumption. Compared to the original system, the power consumption of the sensing array in this study decreases from 8250 to 43.65 mW<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula>h (about 0.529% of the original system) with a measurement interval of 30 min, which is expected to achieve long-term monitoring in the field. The displacement measurement experiment shows that the sensor can measure small displacement changes while diameter of the sensing unit reduces from 9 to 5 cm. At the same time, when two adjacent sensing units within 60° angular range and 50 mm horizontal and vertical displacement range, the average displacement error is less than 1 mm, the maximum error does not exceed 2 mm.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-09-09
DOI
https://doi.org/10.1109/jsen.2024.3452091
Citations
1
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Miniaturized Sensing Unit for Underground Displacement 3-D Measurement Sensor

Wenhao Tang, Guohua Qiu, Nanying Shentu, Qing Li et al.
1 citations
IEEE Sensors Journal
Advanced Sensor and Control Systems
0.33
article

Design of Miniaturized Sensing Unit for Underground Displacement 3-D Measurement Sensor

Wenhao Tang, Guohua Qiu, Nanying Shentu, Qing Li, Yubin Yang, Xianyang Zhang
article en
1 citations

Abstract

Existing underground displacement monitoring sensors require prior drilling, but the size of borehole will affect the workload of drilling. Meanwhile, the landslide monitoring site is often in the field where the traffic is inconvenient and vehicles cannot be directly reached, miniaturization can reduce the weight and volume of the sensor, making transportation and handling even more convenient. Therefore, miniaturization is carried out on the underground displacement 3-D measurement sensor based on double mutual inductance voltage contour method. This study has combined with COMSOL Multiphysics and actual testing, discussing the influence of the air-core coil parameters on sensitivity and measurement range of the sensor, optimizing the parameters of air-core coil inside sensing unit, improving the internal structure of sensing unit to increase the sensitivity of the sensor. Additionally, this study has designed the sensor for low power consumption. Compared to the original system, the power consumption of the sensing array in this study decreases from 8250 to 43.65 mW<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula>h (about 0.529% of the original system) with a measurement interval of 30 min, which is expected to achieve long-term monitoring in the field. The displacement measurement experiment shows that the sensor can measure small displacement changes while diameter of the sensing unit reduces from 9 to 5 cm. At the same time, when two adjacent sensing units within 60° angular range and 50 mm horizontal and vertical displacement range, the average displacement error is less than 1 mm, the maximum error does not exceed 2 mm.

IEEE Sensors JournalVol. 24(20)
China Jiliang University (CN)
Chinese Polar Environment Comprehensive Investigation and Assessment Programmes, Zhejiang Provincial Outstanding Youth Science Foundation
Sustainable cities and communities
Openalex Percentile: Top 42%
Advanced Sensor and Control Systems
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.