Clinical utility of a novel anchor pronged clip for mucosal defect closure after colorectal endoscopic submucosal dissection (with video)

<b>Background and study aims</b> The MANTIS Clip (Boston Scientific) is a novel anchor pronged clip designed to enhance tissue grasping and facilitate the closure of defects in the gastrointestinal tract. This study evaluates the feasibility and effectiveness of the MANTIS Clip for closing mucosal defects following colorectal endoscopic submucosal dissection (C-ESD). <b>Patients and methods</b> A retrospective single-center study was conducted on patients who underwent C-ESD with MANTIS Clip closure from May 2023 to April 2024. The primary outcome measured was the complete closure success rate. Secondary outcomes included defect size, sustained closure rate, closure time, number of clips used, adverse events (AEs), and hospital stay duration. <b>Results</b> The MANTIS Clip was used in 52 cases. The complete closure rate was 98.1% (51/52), with a sustained closure rate of 96.1% (49/51). The median closed defect size was 32 mm, with the largest being 62 mm. The median closure time was 8 minutes. Typically, one MANTIS Clip per defect was used, with only one lesion requiring two clips. The median number of additional clips used was seven. AEs included one case of bleeding (1.9%) and one case of post-ESD coagulation syndrome (1.9%), both managed without extending hospital stays. The median C-reactive protein level on the first day post-ESD was 0.35 mg/dL and the median hospital stay was 5 days. <b>Conclusions</b> The MANTIS Clip is effective and practical for mucosal defect closure post-C-ESD, demonstrating high success and sustained closure rates with minimal complications. Future multicenter randomized trials are needed to further assess its efficacy and safety.

Authors

Institutions

Publication Details

Journal
Endoscopy International Open
Published
2024-09-09
DOI
https://doi.org/10.1055/a-2409-3622
Citations
13
Primary Topic
Gastric Cancer Management and Outcomes
Type
article
Field-Weighted Citation Impact
5.45

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical utility of a novel anchor pronged clip for mucosal defect closure after colorectal endoscopic submucosal dissection (with video)

Mikio MURAOKA, Takayoshi Ito, Tomoaki Kakazu, Daijiro Shiomi et al.
13 citations
Endoscopy International Open
Gastric Cancer Management and Outcomes
5.45
article

Clinical utility of a novel anchor pronged clip for mucosal defect closure after colorectal endoscopic submucosal dissection (with video)

Mikio MURAOKA, Takayoshi Ito, Tomoaki Kakazu, Daijiro Shiomi, Naoyuki Uragami, Masayoshi Kure, Takemasa Hayashi, Haruhiro Inoue, Akiko Toshimori, Rei Miyake, Mayo Tanabe, Akinori Komagata, Yumi Kishi, Hatsuka Nakamura, Noboru Yokoyama, Natsuki Kawamata
article en
13 citations

Abstract

<b>Background and study aims</b> The MANTIS Clip (Boston Scientific) is a novel anchor pronged clip designed to enhance tissue grasping and facilitate the closure of defects in the gastrointestinal tract. This study evaluates the feasibility and effectiveness of the MANTIS Clip for closing mucosal defects following colorectal endoscopic submucosal dissection (C-ESD). <b>Patients and methods</b> A retrospective single-center study was conducted on patients who underwent C-ESD with MANTIS Clip closure from May 2023 to April 2024. The primary outcome measured was the complete closure success rate. Secondary outcomes included defect size, sustained closure rate, closure time, number of clips used, adverse events (AEs), and hospital stay duration. <b>Results</b> The MANTIS Clip was used in 52 cases. The complete closure rate was 98.1% (51/52), with a sustained closure rate of 96.1% (49/51). The median closed defect size was 32 mm, with the largest being 62 mm. The median closure time was 8 minutes. Typically, one MANTIS Clip per defect was used, with only one lesion requiring two clips. The median number of additional clips used was seven. AEs included one case of bleeding (1.9%) and one case of post-ESD coagulation syndrome (1.9%), both managed without extending hospital stays. The median C-reactive protein level on the first day post-ESD was 0.35 mg/dL and the median hospital stay was 5 days. <b>Conclusions</b> The MANTIS Clip is effective and practical for mucosal defect closure post-C-ESD, demonstrating high success and sustained closure rates with minimal complications. Future multicenter randomized trials are needed to further assess its efficacy and safety.

Endoscopy International OpenVol. 12(10)
SHOWA Medical University (JP), SHOWA Medical University Northern Yokohama Hospital (JP), Koto Hospital (JP), SHOWA Medical University Koto Toyosu Hospital (JP)
European Society of Gastrointestinal Endoscopy
Good health and well-being
Openalex Percentile: Top 4%
Gastric Cancer Management and Outcomes
5.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.