Correcting the effect of temperature changes in the measurement results of dielectric response in power transformers as an arrhenius type dielectric with the help of artificial neural network

Abstract Polarization and Depolarization Current (PDC) and Frequency Domain Spectroscopy (FDS) measurements are common dielectric response tests in time and frequency domain that are widely used to diagnosis insulation status in power transformer companies. Numerous factors affect the PDC and FDS test results, which the most important of them is temperature variation. To accurately interpret the results of the dielectric response, the effect of temperature on the results in time and frequency domains, must be corrected. In this paper, firstly a 200 MVA transformer is selected as a test object and FDS and PDC tests are performed on it at different temperatures. Then, based on the FDS results performed on a transformer at different temperatures, the parameters of the insulation model have been estimated by using genetic algorithm (GA). Next, with the help of artificial neural network (ANN), the parameters of the insulation model, related to the different temperatures are transferred into the reference parameters. After that, the parameters of the transferred insulation model, the FDS curves are plotted and transferred to the reference temperature curve and the effect of temperature on them is compensated. By using the correlation of the time and frequency domain results, with the help of transferred insulation model parameters, the PDC results are also plotted and transmitted on the reference PDC curve. Finally, with such a method, the effect of temperature on the PDC results is compensated.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2024-09-09
DOI
https://doi.org/10.1088/1402-4896/ad78c8
Citations
1
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correcting the effect of temperature changes in the measurement results of dielectric response in power transformers as an arrhenius type dielectric with the help of artificial neural network

Seyed Amidedin Mousavi, Mehdi Bigdeli, Masoud Arfaei, Hossein Mohamadi
1 citations
Physica Scripta
Power Transformer Diagnostics and Insulation
0.21
article

Correcting the effect of temperature changes in the measurement results of dielectric response in power transformers as an arrhenius type dielectric with the help of artificial neural network

Seyed Amidedin Mousavi, Mehdi Bigdeli, Masoud Arfaei, Hossein Mohamadi
article en
1 citations

Abstract

Abstract Polarization and Depolarization Current (PDC) and Frequency Domain Spectroscopy (FDS) measurements are common dielectric response tests in time and frequency domain that are widely used to diagnosis insulation status in power transformer companies. Numerous factors affect the PDC and FDS test results, which the most important of them is temperature variation. To accurately interpret the results of the dielectric response, the effect of temperature on the results in time and frequency domains, must be corrected. In this paper, firstly a 200 MVA transformer is selected as a test object and FDS and PDC tests are performed on it at different temperatures. Then, based on the FDS results performed on a transformer at different temperatures, the parameters of the insulation model have been estimated by using genetic algorithm (GA). Next, with the help of artificial neural network (ANN), the parameters of the insulation model, related to the different temperatures are transferred into the reference parameters. After that, the parameters of the transferred insulation model, the FDS curves are plotted and transferred to the reference temperature curve and the effect of temperature on them is compensated. By using the correlation of the time and frequency domain results, with the help of transferred insulation model parameters, the PDC results are also plotted and transmitted on the reference PDC curve. Finally, with such a method, the effect of temperature on the PDC results is compensated.

Physica ScriptaVol. 99(10)
Islamic Azad University of Zanjan (IR)
Openalex Percentile: Top 49%
Power Transformer Diagnostics and Insulation
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.