Solvent optimization and fluorescein lasing for avidin biosensing

• Narrow fluorescein emission is a viable tool for protein biosensing. • Solvent optimization enabled narrow fluorescein emission. • 1:1 methanol-NSS mixture achieves optimal optical performance. • Optimal solvent and energy allow 4.38 nm bandwidth in the Littrow-like cavity. • Spectra changes were observed as a function of the amount of avidin in the solution. We report pulsed laser emission using fluorescein combined with avidin as an active medium matrix in a Littrow-like configuration system. The study covers testing several solvents and a range of excitation energies, aiming to get the narrowest bandwidth for stable peak emission wavelength. Initially, for 4 mM of fluorescein in 1:1 mixture of methanol-NSS, and excited with 20.80mJ of energy, a laser mission of 4.38 nm bandwidth is achieved. Then, different concentrations of thiolated avidin are mixed in the active medium, causing related red-shifts over the initial emission band. Substantial spectral changes are observed down to 0.3 μM of avidin, making apparent the stability conditions for this sort of laser system to work out as a biosensor.

Authors

Institutions

Publication Details

Journal
Materials Letters
Published
2024-09-08
DOI
https://doi.org/10.1016/j.matlet.2024.137377
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Solvent optimization and fluorescein lasing for avidin biosensing

E. Mendicuti, M. Villagrán-Munı́z, M.B. de la Mora, C. Garcı̀a-Segundo
Materials Letters
Advanced Fluorescence Microscopy Techniques
article

Solvent optimization and fluorescein lasing for avidin biosensing

E. Mendicuti, M. Villagrán-Munı́z, M.B. de la Mora, C. Garcı̀a-Segundo
article en

Abstract

• Narrow fluorescein emission is a viable tool for protein biosensing. • Solvent optimization enabled narrow fluorescein emission. • 1:1 methanol-NSS mixture achieves optimal optical performance. • Optimal solvent and energy allow 4.38 nm bandwidth in the Littrow-like cavity. • Spectra changes were observed as a function of the amount of avidin in the solution. We report pulsed laser emission using fluorescein combined with avidin as an active medium matrix in a Littrow-like configuration system. The study covers testing several solvents and a range of excitation energies, aiming to get the narrowest bandwidth for stable peak emission wavelength. Initially, for 4 mM of fluorescein in 1:1 mixture of methanol-NSS, and excited with 20.80mJ of energy, a laser mission of 4.38 nm bandwidth is achieved. Then, different concentrations of thiolated avidin are mixed in the active medium, causing related red-shifts over the initial emission band. Substantial spectral changes are observed down to 0.3 μM of avidin, making apparent the stability conditions for this sort of laser system to work out as a biosensor.

Materials LettersVol. 377
Universidad Nacional Autónoma de México (MX)
Consejo Nacional de Ciencia y Tecnología, Universidad Nacional Autónoma de México, Dirección General de Asuntos del Personal Académico, Universidad Nacional Autónoma de México
Openalex Percentile: Top 90%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.