Enhanced Differentiation of Amiodarone-Induced Thyrotoxicosis Types Using Semi-Quantitative 99mTc-MIBI Uptake Analysis: A Pilot Study

BACKGROUND Technetium (99mTc)-labelled Methoxy-2-Isobutylisonitrile (MIBI) is a diagnostic lipophilic cationic radiotracer used to evaluate the cardiac, breast, thyroid, and parathyroid pathology. This study aimed to evaluate the role of MIBI combined with Tc-99m pertechnetate thyroid scintigraphy, thyroid ultrasonography, and measurement of thyrotropin, thyroid hormones, and autoantibodies to subtype amiodarone-induced thyrotoxicosis (AIT) and the contribution of semi-quantitative analysis of MIBI uptake. MATERIAL AND METHODS This cross-sectional study included 36 patients with AIT who underwent thyrotropin, thyroid hormone, and autoantibody analysis using chemiluminescent method, ultrasonography, pertechnetate, and MIBI thyroid scintigraphy with semi-quantitative uptake, including calculation of the target-to-background ratio (TBR) with 2 different background regions. The MIBI washout rate (WR) was analyzed in all groups. Statistical analysis was performed using descriptive statistics, correlations, and the receiver operating characteristic curve - area under the curve (ROC-AUC). The results were compared with the control group. RESULTS Based on visual and semi-quantitative analyses, patients were successfully categorized into AIT groups (AIT-1, AIT-2 and AIT-3) but the latter method enabled better differentiation of MIBI uptake between all groups. Additionally, ROC-AUC analysis determined cutoff values which enabled discerning between AIT-1 and AIT-2 groups, and AIT-1 and AIT-3 groups. WR showed no significant difference between all AIT groups and controls (P>0.05). CONCLUSIONS Visual MIBI analysis enabled differentiation between AIT-1 and 2 groups, but the method was substantially improved with semi-quantitative analysis, especially in defining AIT-3 group. However, multicenter collaboration with larger studies is needed to standardize the method and obtain more accurate and consistent results.

Authors

Institutions

Publication Details

Journal
Medical Science Monitor
Published
2024-09-02
DOI
https://doi.org/10.12659/msm.945444
Citations
2
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Differentiation of Amiodarone-Induced Thyrotoxicosis Types Using Semi-Quantitative 99mTc-MIBI Uptake Analysis: A Pilot Study

Martina Mavrinac, Tatjana Bogović Crnčić, Andrica Lekić, Dragana Antončić et al.
2 citations
Medical Science Monitor
Radiopharmaceutical Chemistry and Applications
0.81
article

Enhanced Differentiation of Amiodarone-Induced Thyrotoxicosis Types Using Semi-Quantitative 99mTc-MIBI Uptake Analysis: A Pilot Study

Martina Mavrinac, Tatjana Bogović Crnčić, Andrica Lekić, Dragana Antončić, Neva Girotto, Maja Ilić Tomaš, Leo Fischer
article en
2 citations

Abstract

BACKGROUND Technetium (99mTc)-labelled Methoxy-2-Isobutylisonitrile (MIBI) is a diagnostic lipophilic cationic radiotracer used to evaluate the cardiac, breast, thyroid, and parathyroid pathology. This study aimed to evaluate the role of MIBI combined with Tc-99m pertechnetate thyroid scintigraphy, thyroid ultrasonography, and measurement of thyrotropin, thyroid hormones, and autoantibodies to subtype amiodarone-induced thyrotoxicosis (AIT) and the contribution of semi-quantitative analysis of MIBI uptake. MATERIAL AND METHODS This cross-sectional study included 36 patients with AIT who underwent thyrotropin, thyroid hormone, and autoantibody analysis using chemiluminescent method, ultrasonography, pertechnetate, and MIBI thyroid scintigraphy with semi-quantitative uptake, including calculation of the target-to-background ratio (TBR) with 2 different background regions. The MIBI washout rate (WR) was analyzed in all groups. Statistical analysis was performed using descriptive statistics, correlations, and the receiver operating characteristic curve - area under the curve (ROC-AUC). The results were compared with the control group. RESULTS Based on visual and semi-quantitative analyses, patients were successfully categorized into AIT groups (AIT-1, AIT-2 and AIT-3) but the latter method enabled better differentiation of MIBI uptake between all groups. Additionally, ROC-AUC analysis determined cutoff values which enabled discerning between AIT-1 and AIT-2 groups, and AIT-1 and AIT-3 groups. WR showed no significant difference between all AIT groups and controls (P>0.05). CONCLUSIONS Visual MIBI analysis enabled differentiation between AIT-1 and 2 groups, but the method was substantially improved with semi-quantitative analysis, especially in defining AIT-3 group. However, multicenter collaboration with larger studies is needed to standardize the method and obtain more accurate and consistent results.

Medical Science MonitorVol. 30
University Hospital Centre Zagreb (HR), University of Rijeka (HR)
Zero hunger
Openalex Percentile: Top 26%
Radiopharmaceutical Chemistry and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.