Multicenter, multivendor validation of liver quantitative susceptibility mapping in patients with iron overload at 1.5 T and 3 T

QSM as an imaging biomarker of liver iron overload is feasible and repeatable across centers and MR vendors. It may be complementary with <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics> <mml:mrow><mml:msubsup><mml:mi>R</mml:mi> <mml:mn>2</mml:mn> <mml:mo>*</mml:mo></mml:msubsup> </mml:mrow> <mml:annotation>$$ {\mathrm{R}}_2^{\ast } $$</mml:annotation></mml:semantics> </mml:math> as they are obtained from the same acquisition. Although good reproducibility was observed, liver QSM may benefit from standardization of acquisition parameters. Overall, QSM is a promising method for liver iron quantification.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2024-09-05
DOI
https://doi.org/10.1002/mrm.30251
Citations
1
Primary Topic
Hemoglobinopathies and Related Disorders
Type
article
Field-Weighted Citation Impact
0.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multicenter, multivendor validation of liver quantitative susceptibility mapping in patients with iron overload at 1.5 T and 3 T

Ryan J. Mattison, Collin J. Buelo, Qing Yuan, Dimitrios C. Karampinos et al.
1 citations
Magnetic Resonance in Medicine
Hemoglobinopathies and Related Disorders
0.44
article

Multicenter, multivendor validation of liver quantitative susceptibility mapping in patients with iron overload at 1.5 T and 3 T

Ryan J. Mattison, Collin J. Buelo, Qing Yuan, Dimitrios C. Karampinos, Mounes Aliyari Ghasabeh, Julia Velikina, Lu Mao, Iván Pedrosa, Diego Hernando, Michael Jeng, Scott B. Reeder, Ihab R. Kamel, Ruiyang Zhao, Shreyas Vasanawala, Takeshi Yokoo, David Harris, Stefan Ruschke
article en
1 citations

Abstract

QSM as an imaging biomarker of liver iron overload is feasible and repeatable across centers and MR vendors. It may be complementary with <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics> <mml:mrow><mml:msubsup><mml:mi>R</mml:mi> <mml:mn>2</mml:mn> <mml:mo>*</mml:mo></mml:msubsup> </mml:mrow> <mml:annotation>$$ {\mathrm{R}}_2^{\ast } $$</mml:annotation></mml:semantics> </mml:math> as they are obtained from the same acquisition. Although good reproducibility was observed, liver QSM may benefit from standardization of acquisition parameters. Overall, QSM is a promising method for liver iron quantification.

Magnetic Resonance in MedicineVol. 93(1)
University of Wisconsin–Madison (US), TUM Klinikum (DE), Advanced Imaging Research (United States) (US), Technical University of Munich (DE), The University of Texas Southwestern Medical Center (US), Stanford University (US)
National Institutes of Health
Openalex Percentile: Top 33%
Hemoglobinopathies and Related Disorders
0.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.