Experimental study on the flexural performance of concrete hollow composite slabs with tightly connected panel sides

The performance of joint connections in composite slabs is crucial for ensuring their bidirectional load-bearing capacity and overall structural integrity. To effectively address the challenge of protruding rebar in precast components, a new structural form of a tightly connected hollow concrete composite slab without protruding rebar on the slab side is proposed. To investigate the mechanical performance and failure modes of this slab-side tight-joint connected hollow concrete composite slab, bending performance tests under monotonic load were conducted on three tightly connected hollow composite slabs and one seamless hollow composite slab. The analysis focused on the failure modes, crack distribution, bending capacity, and bending stiffness of additional steel bars at the joints of the slabs. The results indicate that, under normal operating conditions, the flexural performance development of concrete hollow composite slabs with tightly connected slab sides is generally consistent with that of the non-spliced cast hollow composite slab. Under ultimate conditions, tearing or brittle fracture failure at the joint interface is likely to occur in the composite slabs, leading to a reduction in flexural bearing capacity. With an increase in joints, the bending capacity of the hollow composite slab decreases by 17.1%, Conversely, when joints are positioned away from the most stressed section, the flexural stiffness of the section increases by 13.5%. A comparison of experimental data and theoretical calculations indicates that the additional rebar at the joints effectively contributes to the lateral load transfer in the hollow composite slab, achieving bidirectional load-bearing capacity. This further validates that the design of the single-joint, tight-joint connected hollow concrete composite slab without protruding rebar meets the requirements for bidirectional load-bearing performance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-09-06
DOI
https://doi.org/10.1038/s41598-024-71880-8
Citations
4
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on the flexural performance of concrete hollow composite slabs with tightly connected panel sides

Qinyong Ma, Xudong Chen
4 citations
Scientific Reports
Structural Behavior of Reinforced Concrete
1.06
article

Experimental study on the flexural performance of concrete hollow composite slabs with tightly connected panel sides

Qinyong Ma, Xudong Chen
article en
4 citations

Abstract

The performance of joint connections in composite slabs is crucial for ensuring their bidirectional load-bearing capacity and overall structural integrity. To effectively address the challenge of protruding rebar in precast components, a new structural form of a tightly connected hollow concrete composite slab without protruding rebar on the slab side is proposed. To investigate the mechanical performance and failure modes of this slab-side tight-joint connected hollow concrete composite slab, bending performance tests under monotonic load were conducted on three tightly connected hollow composite slabs and one seamless hollow composite slab. The analysis focused on the failure modes, crack distribution, bending capacity, and bending stiffness of additional steel bars at the joints of the slabs. The results indicate that, under normal operating conditions, the flexural performance development of concrete hollow composite slabs with tightly connected slab sides is generally consistent with that of the non-spliced cast hollow composite slab. Under ultimate conditions, tearing or brittle fracture failure at the joint interface is likely to occur in the composite slabs, leading to a reduction in flexural bearing capacity. With an increase in joints, the bending capacity of the hollow composite slab decreases by 17.1%, Conversely, when joints are positioned away from the most stressed section, the flexural stiffness of the section increases by 13.5%. A comparison of experimental data and theoretical calculations indicates that the additional rebar at the joints effectively contributes to the lateral load transfer in the hollow composite slab, achieving bidirectional load-bearing capacity. This further validates that the design of the single-joint, tight-joint connected hollow concrete composite slab without protruding rebar meets the requirements for bidirectional load-bearing performance.

Scientific ReportsVol. 14(1)
Anhui Jianzhu University (CN), Anhui University (CN), Anhui University of Science and Technology (CN)
Sustainable cities and communities
Openalex Percentile: Top 25%
Structural Behavior of Reinforced Concrete
1.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.