Investigation of Pressure Signal and Leak Detection in Pipes by Using Wavelet Transform in Transient Flow

Leakages in pipes lead to water loss, so leak detection to prevent water loss is essential. Transient flow is a method to obtain a wide range of pipe flow data, but generally, signal data have various noises also related to leakages. One effective way to detect leaks is to use wavelet transform (WT). So, in this study, by conducting laboratory experiments and using WT, the behavior of the signal and the effectiveness of wavelet transform were investigated. Results of the research showed that WT is very effective for leak detection, noise reduction, and signal analysis for transient flow.

Authors

Institutions

Publication Details

Published
2024-09-06
DOI
https://doi.org/10.3390/engproc2024069076
Citations
1
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Pressure Signal and Leak Detection in Pipes by Using Wavelet Transform in Transient Flow

Roberto Ranzi, Mostafa Rahmanshahi, Hossein Azizi Nadian, Mahmood Shafaei Bejestan et al.
1 citations
Water Systems and Optimization
0.26
article

Investigation of Pressure Signal and Leak Detection in Pipes by Using Wavelet Transform in Transient Flow

Roberto Ranzi, Mostafa Rahmanshahi, Hossein Azizi Nadian, Mahmood Shafaei Bejestan, N. Rad
article en
1 citations

Abstract

Leakages in pipes lead to water loss, so leak detection to prevent water loss is essential. Transient flow is a method to obtain a wide range of pipe flow data, but generally, signal data have various noises also related to leakages. One effective way to detect leaks is to use wavelet transform (WT). So, in this study, by conducting laboratory experiments and using WT, the behavior of the signal and the effectiveness of wavelet transform were investigated. Results of the research showed that WT is very effective for leak detection, noise reduction, and signal analysis for transient flow.

Hong Kong Polytechnic University (HK), Shahid Chamran University of Ahvaz (IR), University of Brescia (IT)
Shahid Chamran University of Ahvaz, Università degli Studi di Brescia
Openalex Percentile: Top 45%
Water Systems and Optimization
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of Pressure Signal and Leak Detection in Pipes by Using Wavelet Transform in Transient Flow — Roberto Ranzi, Mostafa Rahmanshahi, et al. · (2024) | TGRS Research Map | TGRS