Comparative Analysis of QCM and Electrochemical Aptasensors for SARS-CoV-2 Detection

The rapid and accurate detection of SARS-CoV-2, particularly its spike receptor-binding domain (S-RBD), was crucial for managing the COVID-19 pandemic. This study presents the development and optimization of two types of aptasensors: quartz crystal microbalance (QCM) and electrochemical sensors, both employing thiol-modified DNA aptamers for S-RBD detection. The QCM aptasensor demonstrated exceptional sensitivity, achieved by optimizing aptamer concentration, buffer composition, and pre-treatment conditions, with a limit of detection (LOD) of 0.07 pg/mL and a linear range from 1 pg/mL to 0.1 µg/mL, and a significant frequency change was observed upon target binding. The electrochemical aptasensor, designed for rapid and efficient preparation, utilized a one-step modification process that reduced the preparation time to 2 h while maintaining high sensitivity and specificity. Electrochemical impedance spectroscopy (EIS) enabled the detection of S-RBD concentrations as low as 132 ng/mL. Both sensors exhibited high specificity, with negligible non-specific interactions observed in the presence of competing proteins. Additionally, the QCM aptasensor's functionality and stability were verified in biological fluids, indicating its potential for real-world applications. This study highlights the comparative advantages of QCM and electrochemical aptasensors in terms of preparation time, sensitivity, and specificity, offering valuable insights for the development of rapid, sensitive, and specific diagnostic tools for the detection of SARS-CoV-2 and other viruses.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2024-09-06
DOI
https://doi.org/10.3390/bios14090431
Citations
7
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of QCM and Electrochemical Aptasensors for SARS-CoV-2 Detection

Katarína Nemčeková, Miroslav Gál, Veronika Svitková, Alexandra Poturnayová et al.
7 citations
Biosensors
Advanced biosensing and bioanalysis techniques
1.64
article

Comparative Analysis of QCM and Electrochemical Aptasensors for SARS-CoV-2 Detection

Katarína Nemčeková, Miroslav Gál, Veronika Svitková, Alexandra Poturnayová, Michaela Domšicová, Jana Korčeková, Denis Baraniak, Michaela Hornychová, Viktória Szebellaiová, Eva Melníková
article en
7 citations

Abstract

The rapid and accurate detection of SARS-CoV-2, particularly its spike receptor-binding domain (S-RBD), was crucial for managing the COVID-19 pandemic. This study presents the development and optimization of two types of aptasensors: quartz crystal microbalance (QCM) and electrochemical sensors, both employing thiol-modified DNA aptamers for S-RBD detection. The QCM aptasensor demonstrated exceptional sensitivity, achieved by optimizing aptamer concentration, buffer composition, and pre-treatment conditions, with a limit of detection (LOD) of 0.07 pg/mL and a linear range from 1 pg/mL to 0.1 µg/mL, and a significant frequency change was observed upon target binding. The electrochemical aptasensor, designed for rapid and efficient preparation, utilized a one-step modification process that reduced the preparation time to 2 h while maintaining high sensitivity and specificity. Electrochemical impedance spectroscopy (EIS) enabled the detection of S-RBD concentrations as low as 132 ng/mL. Both sensors exhibited high specificity, with negligible non-specific interactions observed in the presence of competing proteins. Additionally, the QCM aptasensor's functionality and stability were verified in biological fluids, indicating its potential for real-world applications. This study highlights the comparative advantages of QCM and electrochemical aptasensors in terms of preparation time, sensitivity, and specificity, offering valuable insights for the development of rapid, sensitive, and specific diagnostic tools for the detection of SARS-CoV-2 and other viruses.

BiosensorsVol. 14(9)
Slovak University of Technology in Bratislava (SK), Slovak Academy of Sciences (SK), Centre of Biosciences of the Slovak Academy of Sciences (SK)
Openalex Percentile: Top 16%
Advanced biosensing and bioanalysis techniques
1.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.