Investigation of the Upper Safety Operating Pressure Limit for Underground Gas Storage Using the Fault Activation Pressure Evaluation Method

As a crucial reserve for natural gas, the safe operation of underground gas storage facilities is paramount for seasonal peak shaving and emergency supply security. Focusing on the Lei X gas storage facility in the Liaohe Basin of China, this study delves into the mechanical integrity of gas storage facilities and assesses the upper limit pressure for safe operation. Leveraging seismic logging data, we conducted an analysis and statistical evaluation of boundary faults and top cover characteristics, integrating regional stress fields and rock mechanics to evaluate fault activation pressure and cover failure risk using a fault activation pressure assessment method. This research elucidates the maximum safe operating pressure for underground gas storage facilities. The research findings suggest that the sealing layer of the Lei X gas storage reservoir exhibits a predominant hydro-fracturing pattern. Under the existing stress field conditions, the sealing layer demonstrates favorable sealing properties, and the boundary faults remain relatively stable. Moreover, through data extraction and quantitative analysis, this study clearly determined the critical pressure at which each fault is activated and the pressure at which the sealing layer undergoes hydro-fracturing during cyclic injection and the production of gas storage. Considering the activation pressure and fracturing pressure data for the sealing layer, a secure operating pressure of 15.0 MPa was calculated for gas storage operations. This study offers crucial theoretical support for enhancing injection and production efficiency, as well as ensuring the safe operation of Lei X gas storage and providing technical guidance for future adjustments to injection and production schemes.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-09-06
DOI
https://doi.org/10.3390/pr12091910
Citations
1
Primary Topic
CO2 Sequestration and Geologic Interactions
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the Upper Safety Operating Pressure Limit for Underground Gas Storage Using the Fault Activation Pressure Evaluation Method

Lingdong Meng, Yejun Jin, Haibo Wen, Tianguang Zhang et al.
1 citations
Processes
CO2 Sequestration and Geologic Interactions
0.21
article

Investigation of the Upper Safety Operating Pressure Limit for Underground Gas Storage Using the Fault Activation Pressure Evaluation Method

Lingdong Meng, Yejun Jin, Haibo Wen, Tianguang Zhang, Xianxue Chen
article en
1 citations

Abstract

As a crucial reserve for natural gas, the safe operation of underground gas storage facilities is paramount for seasonal peak shaving and emergency supply security. Focusing on the Lei X gas storage facility in the Liaohe Basin of China, this study delves into the mechanical integrity of gas storage facilities and assesses the upper limit pressure for safe operation. Leveraging seismic logging data, we conducted an analysis and statistical evaluation of boundary faults and top cover characteristics, integrating regional stress fields and rock mechanics to evaluate fault activation pressure and cover failure risk using a fault activation pressure assessment method. This research elucidates the maximum safe operating pressure for underground gas storage facilities. The research findings suggest that the sealing layer of the Lei X gas storage reservoir exhibits a predominant hydro-fracturing pattern. Under the existing stress field conditions, the sealing layer demonstrates favorable sealing properties, and the boundary faults remain relatively stable. Moreover, through data extraction and quantitative analysis, this study clearly determined the critical pressure at which each fault is activated and the pressure at which the sealing layer undergoes hydro-fracturing during cyclic injection and the production of gas storage. Considering the activation pressure and fracturing pressure data for the sealing layer, a secure operating pressure of 15.0 MPa was calculated for gas storage operations. This study offers crucial theoretical support for enhancing injection and production efficiency, as well as ensuring the safe operation of Lei X gas storage and providing technical guidance for future adjustments to injection and production schemes.

ProcessesVol. 12(9)
Second Hospital of Liaohe Oilfield (CN), Northeast Petroleum University (CN)
Openalex Percentile: Top 51%
CO2 Sequestration and Geologic Interactions
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.