High-Resolution Intact Protein Analysis via Phase-Modulated, Stepwise Frequency Scan Ion Trap Mass Spectrometry

Mass spectrometry (MS) using an electron multiplier for intact protein analysis remains limited. Because of the massive size and complex structure of proteins, the slow flight speed of their ions results in few secondary electrons and thus low detection sensitivity and poor spectral resolution. Thus, we present a compact ion trap-mass spectrometry approach to directly detect ion packets and obtain the high-resolution molecular signature of proteins. The disturbances causing deviations of ion motion and mass conversion have been clarified in advance. The radio frequency waveform used to manipulate ions is proposed to be a sequence of constant-frequency steps, interconnected by short time-outs, resulting in least dispersive distortion. Furthermore, more such constant-phase conjunctions are arranged in each step to compensate for fluctuations resulting from defects in the system and operation. In addition, two auxiliary pulses are generated in the right phase of each step to select ions of a specific secular state to detect one clean and sharp spectral line.This study demonstrates a top-down approach for the MS measurement of cytochrome C molecules, resulting in a spectral profile of the protein in its natural state at a resolution of 20 Da. Additionally, quick MS scans of other proteins were performed.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-09-06
DOI
https://doi.org/10.1021/acs.analchem.4c02775
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Resolution Intact Protein Analysis via Phase-Modulated, Stepwise Frequency Scan Ion Trap Mass Spectrometry

Fang Hsu Chen, Chun-Yen Cheng, Cheng‐Han Yang, I‐Chung Lu et al.
Analytical Chemistry
Mass Spectrometry Techniques and Applications
article

High-Resolution Intact Protein Analysis via Phase-Modulated, Stepwise Frequency Scan Ion Trap Mass Spectrometry

Fang Hsu Chen, Chun-Yen Cheng, Cheng‐Han Yang, I‐Chung Lu, Ming‐Long Yeh, Szu-Wei Chou
article en

Abstract

Mass spectrometry (MS) using an electron multiplier for intact protein analysis remains limited. Because of the massive size and complex structure of proteins, the slow flight speed of their ions results in few secondary electrons and thus low detection sensitivity and poor spectral resolution. Thus, we present a compact ion trap-mass spectrometry approach to directly detect ion packets and obtain the high-resolution molecular signature of proteins. The disturbances causing deviations of ion motion and mass conversion have been clarified in advance. The radio frequency waveform used to manipulate ions is proposed to be a sequence of constant-frequency steps, interconnected by short time-outs, resulting in least dispersive distortion. Furthermore, more such constant-phase conjunctions are arranged in each step to compensate for fluctuations resulting from defects in the system and operation. In addition, two auxiliary pulses are generated in the right phase of each step to select ions of a specific secular state to detect one clean and sharp spectral line.This study demonstrates a top-down approach for the MS measurement of cytochrome C molecules, resulting in a spectral profile of the protein in its natural state at a resolution of 20 Da. Additionally, quick MS scans of other proteins were performed.

Analytical ChemistryVol. 96(37)
National Chung Hsing University (TW), National Cheng Kung University (TW)
National Cheng Kung University, Medical Device Innovation Center, National Science and Technology Council
Openalex Percentile: Top 89%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Resolution Intact Protein Analysis via Phase-Modulated, Stepwise Frequency Scan Ion Trap Mass Spectrometry — Fang Hsu Chen, Chun-Yen Cheng, et al. · Analytical Chemistry (2024) | TGRS Research Map | TGRS