Thermodynamic Comparative Analysis of Cascade Refrigeration System Pairing R744 with R404A, R448A, and R449A with Internal Heat Exchanger: Part 1—Coefficient of Performance Characteristics

The R744/R404A cascade refrigeration system (CRS) has been widely used in supermarkets and hypermarkets, but due to the refrigerant regulation of R404A, research on alternative refrigerants is necessary. In addition, although there have been quite a few studies on R448A and R449A, which are well-known alternatives to R404A, few studies have analyzed the performance coefficients of the three refrigerants, and the studies that have analyzed them are not based on enough variables. Therefore, we aimed to understand the performance characteristics of CRS combined with an internal heat exchanger (IHX) by applying R744 for the low-temperature cycle (LTC) and R404A, R448A, and R449A for the high-temperature cycle (HTC). The analysis method was to analyze the coefficient of performance (COP) and mass flow rate (MFR) of the three refrigerants according to the degree of subcooling (DSC) and degree of superheating (DSH), IHX efficiency, temperature difference in the cascade heat exchanger (CHX), condensation temperature (CT), evaporation temperature (ET), and cascade evaporation temperature (CET). The purpose of this study is to compare R448A and R449A, alternative refrigerants to R404A, in an R744/R404A CRS, with R404A to provide sufficient data for optimal CRS design. The comparison results are as follows: (1) Compared with R404A, the MFR of R448A and R449A are 67.27–77.6% and 70.05–80.80%, respectively, under the same conditions. Therefore, R448A and R449A are economically favorable because they have less refrigerant charge than R404A, and R448A is more favorable than R449A. (2) The R744/R448A CRS is stable and performs better than the R744/R449A CRS in places with large changes in the surrounding environment.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-06
DOI
https://doi.org/10.3390/en17174481
Citations
2
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermodynamic Comparative Analysis of Cascade Refrigeration System Pairing R744 with R404A, R448A, and R449A with Internal Heat Exchanger: Part 1—Coefficient of Performance Characteristics

Joon-Hyuk Lee, Min-Ju Jeon
2 citations
Energies
Refrigeration and Air Conditioning Technologies
0.43
article

Thermodynamic Comparative Analysis of Cascade Refrigeration System Pairing R744 with R404A, R448A, and R449A with Internal Heat Exchanger: Part 1—Coefficient of Performance Characteristics

Joon-Hyuk Lee, Min-Ju Jeon
article en
2 citations

Abstract

The R744/R404A cascade refrigeration system (CRS) has been widely used in supermarkets and hypermarkets, but due to the refrigerant regulation of R404A, research on alternative refrigerants is necessary. In addition, although there have been quite a few studies on R448A and R449A, which are well-known alternatives to R404A, few studies have analyzed the performance coefficients of the three refrigerants, and the studies that have analyzed them are not based on enough variables. Therefore, we aimed to understand the performance characteristics of CRS combined with an internal heat exchanger (IHX) by applying R744 for the low-temperature cycle (LTC) and R404A, R448A, and R449A for the high-temperature cycle (HTC). The analysis method was to analyze the coefficient of performance (COP) and mass flow rate (MFR) of the three refrigerants according to the degree of subcooling (DSC) and degree of superheating (DSH), IHX efficiency, temperature difference in the cascade heat exchanger (CHX), condensation temperature (CT), evaporation temperature (ET), and cascade evaporation temperature (CET). The purpose of this study is to compare R448A and R449A, alternative refrigerants to R404A, in an R744/R404A CRS, with R404A to provide sufficient data for optimal CRS design. The comparison results are as follows: (1) Compared with R404A, the MFR of R448A and R449A are 67.27–77.6% and 70.05–80.80%, respectively, under the same conditions. Therefore, R448A and R449A are economically favorable because they have less refrigerant charge than R404A, and R448A is more favorable than R449A. (2) The R744/R448A CRS is stable and performs better than the R744/R449A CRS in places with large changes in the surrounding environment.

EnergiesVol. 17(17)
Pukyong National University (KR)
Openalex Percentile: Top 43%
Refrigeration and Air Conditioning Technologies
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.