Geometric correction of cone beam computed laminography based on projected address translation

Precise alignment of the system scan geometry is crucial to the reconstruction quality of computed laminography (CL). Different from computed tomography (CT), a challenging task for CL image reconstruction is to deal with rotational axes that are no longer symmetrical. In this paper, we take advantage of the fact that the difference between the inverse of the projected transverse coordinates of two points rotated about the axis of rotation under the CL scan geometry sums to zero when the projection angle differs by 180 deg. Based on this fact, the projection data under the scanned geometry with errors are aligned to the theoretical projection geometry. To validate this calibration method, a numerical printed circuit board (PCB) phantom was simulated. The results demonstrate that this method is capable of achieving high accuracy compared to the previous methods. The experimental results on printed circuit boards (PCB) demonstrate that the method can effectively improve geometric alignment accuracy of CL and obtain high-resolution reconstructed images.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2024-09-06
DOI
https://doi.org/10.1364/ao.529700
Citations
2
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geometric correction of cone beam computed laminography based on projected address translation

Gengyang Chen, Rongsheng Lu, Pan He, Siyuan Shen et al.
2 citations
Applied Optics
Optical measurement and interference techniques
0.50
article

Geometric correction of cone beam computed laminography based on projected address translation

Gengyang Chen, Rongsheng Lu, Pan He, Siyuan Shen, Hao Li, Ziyang Mu
article en
2 citations

Abstract

Precise alignment of the system scan geometry is crucial to the reconstruction quality of computed laminography (CL). Different from computed tomography (CT), a challenging task for CL image reconstruction is to deal with rotational axes that are no longer symmetrical. In this paper, we take advantage of the fact that the difference between the inverse of the projected transverse coordinates of two points rotated about the axis of rotation under the CL scan geometry sums to zero when the projection angle differs by 180 deg. Based on this fact, the projection data under the scanned geometry with errors are aligned to the theoretical projection geometry. To validate this calibration method, a numerical printed circuit board (PCB) phantom was simulated. The results demonstrate that this method is capable of achieving high accuracy compared to the previous methods. The experimental results on printed circuit boards (PCB) demonstrate that the method can effectively improve geometric alignment accuracy of CL and obtain high-resolution reconstructed images.

Applied OpticsVol. 63(27)
Anhui University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 35%
Optical measurement and interference techniques
0.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.