A Non-Intrusive Load Decomposition Model Based on Multiple Electrical Parameters to Point

The sliding window method is commonly used for non-intrusive load disaggregation. However, it is difficult to choose the appropriate window size, and the disaggregation effect is poor in low-frequency industrial environments. To better handle low-frequency industrial load data, in this paper, we propose a vertical non-intrusive load disaggregation model that is different from the sliding window method. By training multiple electrical parameters at a single point on the bus end with the corresponding load data at the branch end, the proposed method, called multiple electrical parameters to point (Mep2point), takes the electrical parameter data sampled at a single point on the bus end as its input and outputs the load data of the target device sampled at the corresponding point. First, the electrical parameters of the bus end are processed, and each item is normalized to the range from 0–1. Then, the electrical parameters are vertically arranged by their time point, and a convolutional neural network (CNN) is used to train the model. The proposed method is analyzed on low-frequency industrial user data sampled at a frequency of 1/120 Hz in the real world. We compare our method with three advanced sliding window methods, achieving an average improvement ranging from 9.23% to 22.51% in evaluation metrics, while showing substantial superiority in the actual decomposed images. Compared with three classical machine learning algorithms, our model, using the same amount of data, significantly outperforms these methods. Finally, we also compared our method with the multi-channel low window sequence-to-point (MLSP) method, which also selects multiple electrical parameters. Our model’s complexity is much less than that of the MLSP model, and its performance remains high. The superiority of our model, as presented in this paper, is fully verified by experimental analysis, which can produce better actual load decomposition results from each branch and contribute to the analysis and monitoring of loads in industrial environments.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-06
DOI
https://doi.org/10.3390/en17174482
Primary Topic
Smart Grid Energy Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Non-Intrusive Load Decomposition Model Based on Multiple Electrical Parameters to Point

Xinyuan Liu, Meng Yang, Zhiyou Cheng
Energies
Smart Grid Energy Management
article

A Non-Intrusive Load Decomposition Model Based on Multiple Electrical Parameters to Point

Xinyuan Liu, Meng Yang, Zhiyou Cheng
article en

Abstract

The sliding window method is commonly used for non-intrusive load disaggregation. However, it is difficult to choose the appropriate window size, and the disaggregation effect is poor in low-frequency industrial environments. To better handle low-frequency industrial load data, in this paper, we propose a vertical non-intrusive load disaggregation model that is different from the sliding window method. By training multiple electrical parameters at a single point on the bus end with the corresponding load data at the branch end, the proposed method, called multiple electrical parameters to point (Mep2point), takes the electrical parameter data sampled at a single point on the bus end as its input and outputs the load data of the target device sampled at the corresponding point. First, the electrical parameters of the bus end are processed, and each item is normalized to the range from 0–1. Then, the electrical parameters are vertically arranged by their time point, and a convolutional neural network (CNN) is used to train the model. The proposed method is analyzed on low-frequency industrial user data sampled at a frequency of 1/120 Hz in the real world. We compare our method with three advanced sliding window methods, achieving an average improvement ranging from 9.23% to 22.51% in evaluation metrics, while showing substantial superiority in the actual decomposed images. Compared with three classical machine learning algorithms, our model, using the same amount of data, significantly outperforms these methods. Finally, we also compared our method with the multi-channel low window sequence-to-point (MLSP) method, which also selects multiple electrical parameters. Our model’s complexity is much less than that of the MLSP model, and its performance remains high. The superiority of our model, as presented in this paper, is fully verified by experimental analysis, which can produce better actual load decomposition results from each branch and contribute to the analysis and monitoring of loads in industrial environments.

EnergiesVol. 17(17)
Anhui University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 88%
Smart Grid Energy Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.