Use of a Skin-Fixed Dynamic Reference Frame in Spinal Trauma Surgery: A Case Report

Intraoperative CT navigation has revolutionized spinal surgery by enhancing precision, particularly in pedicle screw placement. However, the traditional use of bone-fixed dynamic reference frames (DRFs) often necessitates placement on spinous processes, complicating percutaneous pedicle screw (PPS) insertion and requiring additional incisions. This case report presents a novel approach utilizing a skin-fixed DRF in spinal trauma surgery. A 26-year-old female sustained lower limb paralysis, sensory impairment, and bladder-rectal dysfunction after a 15 m fall, resulting in an L1 fracture-dislocation (American Spinal Injury Association score C, Thoracolumbar AOSpine Injury Score score 13). The radiological assessment confirmed dural sac compression. An emergency damage control surgery was conducted using a skin-fixed DRF, secured with sutures and tape near the PPS insertion site. Intraoperative CT navigation guided the insertion of PPS from T11 to L3. The procedure lasted 141 minutes with an estimated blood loss of 256 mL. Postoperative CT verified accurate screw placement. At six months postoperatively, the patient exhibited significant motor recovery and regained independent ambulation. The skin-fixed DRF technique minimizes surgical complexity, obviates the need for additional incisions, and mitigates the challenges associated with bone-fixed DRFs during PPS procedures. This method demonstrates potential as a minimally invasive and effective surgical technique in spinal trauma cases.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-09-06
DOI
https://doi.org/10.7759/cureus.68777
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of a Skin-Fixed Dynamic Reference Frame in Spinal Trauma Surgery: A Case Report

Akihiko Hiyama, Masahiko Watanabe, Daisuke Sakai, Nobuaki Hattori et al.
Cureus
Spinal Fractures and Fixation Techniques
article

Use of a Skin-Fixed Dynamic Reference Frame in Spinal Trauma Surgery: A Case Report

Akihiko Hiyama, Masahiko Watanabe, Daisuke Sakai, Nobuaki Hattori, Tatsuya Kishi
article en

Abstract

Intraoperative CT navigation has revolutionized spinal surgery by enhancing precision, particularly in pedicle screw placement. However, the traditional use of bone-fixed dynamic reference frames (DRFs) often necessitates placement on spinous processes, complicating percutaneous pedicle screw (PPS) insertion and requiring additional incisions. This case report presents a novel approach utilizing a skin-fixed DRF in spinal trauma surgery. A 26-year-old female sustained lower limb paralysis, sensory impairment, and bladder-rectal dysfunction after a 15 m fall, resulting in an L1 fracture-dislocation (American Spinal Injury Association score C, Thoracolumbar AOSpine Injury Score score 13). The radiological assessment confirmed dural sac compression. An emergency damage control surgery was conducted using a skin-fixed DRF, secured with sutures and tape near the PPS insertion site. Intraoperative CT navigation guided the insertion of PPS from T11 to L3. The procedure lasted 141 minutes with an estimated blood loss of 256 mL. Postoperative CT verified accurate screw placement. At six months postoperatively, the patient exhibited significant motor recovery and regained independent ambulation. The skin-fixed DRF technique minimizes surgical complexity, obviates the need for additional incisions, and mitigates the challenges associated with bone-fixed DRFs during PPS procedures. This method demonstrates potential as a minimally invasive and effective surgical technique in spinal trauma cases.

CureusVol. 16(9)
Tokai University (JP), Tokai University Hospital (JP)
Gender equality
Openalex Percentile: Top 72%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Use of a Skin-Fixed Dynamic Reference Frame in Spinal Trauma Surgery: A Case Report — Akihiko Hiyama, Masahiko Watanabe, et al. · Cureus (2024) | TGRS Research Map | TGRS