Prediction of Air Purifier Effectiveness for Eliminating Exhaled Droplets in a Confined Room

High-efficiency particulate air (HEPA) filter purifiers are a recommended method for eliminating respiratory airborne droplets. In this study, the movement of airborne droplets exhaled by occupants in an unventilated, two-bed dormitory room with an air purifier was simulated using computational fluid dynamics. The air was modeled using an Eulerian scheme while the droplets were modeled using a Lagrangian method. The airborne droplet number, the rate at which droplets are removed, and the rate at which droplets accumulate were calculated. A larger HEPA flow rate increased the droplet removal efficiency, with most of the droplets settling on boundary surfaces. Of particular note, the air purifier location within the room had a significant impact on reducing the droplet exchange between two occupants and improving the droplet elimination efficiency.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-09-06
DOI
https://doi.org/10.3390/pr12091917
Citations
2
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prediction of Air Purifier Effectiveness for Eliminating Exhaled Droplets in a Confined Room

Yumeng Zhao, Kingsly Ambrose, Carl Wassgren, Alexander Russell
2 citations
Processes
Infection Control and Ventilation
0.84
article

Prediction of Air Purifier Effectiveness for Eliminating Exhaled Droplets in a Confined Room

Yumeng Zhao, Kingsly Ambrose, Carl Wassgren, Alexander Russell
article en
2 citations

Abstract

High-efficiency particulate air (HEPA) filter purifiers are a recommended method for eliminating respiratory airborne droplets. In this study, the movement of airborne droplets exhaled by occupants in an unventilated, two-bed dormitory room with an air purifier was simulated using computational fluid dynamics. The air was modeled using an Eulerian scheme while the droplets were modeled using a Lagrangian method. The airborne droplet number, the rate at which droplets are removed, and the rate at which droplets accumulate were calculated. A larger HEPA flow rate increased the droplet removal efficiency, with most of the droplets settling on boundary surfaces. Of particular note, the air purifier location within the room had a significant impact on reducing the droplet exchange between two occupants and improving the droplet elimination efficiency.

ProcessesVol. 12(9)
Purdue University West Lafayette (US), AbbVie (Germany) (DE)
Openalex Percentile: Top 24%
Infection Control and Ventilation
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.