Comparison of Reactive Power Compensation Methods in an Industrial Electrical System with Power Quality Problems

This paper compares concentrated and distributed reactive power compensation to improve the power factor at the point of common connection (PCC) of an industrial electrical system (IES) with harmonics. The electrical system under study has a low power factor, voltage variation, and harmonics caused by motors operating at low loads and powered by variable-speed drives. The designed compensation system mitigates harmonics and reduces electrical losses with the shortest payback period. Four solutions were compared, considering concentrated and distributed compensation with capacitor banks and harmonic filters. Although the cost of investment in concentrated compensation is lower than that of distributed compensation, a higher reduction in electrical losses and a lower payback period are obtained with distributed compensation. Although the lowest payback period was obtained with distributed compensation with capacitor banks (0.4 years), it is not recommended in the presence of harmonics because the effects of current harmonics significantly reduce the useful life of these elements. For this reason, distributed compensation with harmonic filters obtained a payback period of 0.6 years, and it was proposed as the best solution. These results should be considered in projects aimed at power factor compensation in IESs with harmonics. The concentrated compensation of the capacitor bank at the PCC is proposed because of the lower investment cost and ease of installation. However, the advantages of distributed compensation with harmonic filters have not been evaluated. An energy efficiency approach is used to analyze the impact of the location methods of the power factor compensation equipment on the electrical losses of the IES.

Authors

Institutions

Publication Details

Journal
Electricity
Published
2024-09-06
DOI
https://doi.org/10.3390/electricity5030032
Citations
9
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Reactive Power Compensation Methods in an Industrial Electrical System with Power Quality Problems

Vladimir Sousa Santos, Jorge De La Cruz, John Edwin Candelo-Becerra, Salim Adolfo Giha Yidi et al.
9 citations
Electricity
Power Quality and Harmonics
1.88
article

Comparison of Reactive Power Compensation Methods in an Industrial Electrical System with Power Quality Problems

Vladimir Sousa Santos, Jorge De La Cruz, John Edwin Candelo-Becerra, Salim Adolfo Giha Yidi, Kelly Berdugo Sarmiento
article en
9 citations

Abstract

This paper compares concentrated and distributed reactive power compensation to improve the power factor at the point of common connection (PCC) of an industrial electrical system (IES) with harmonics. The electrical system under study has a low power factor, voltage variation, and harmonics caused by motors operating at low loads and powered by variable-speed drives. The designed compensation system mitigates harmonics and reduces electrical losses with the shortest payback period. Four solutions were compared, considering concentrated and distributed compensation with capacitor banks and harmonic filters. Although the cost of investment in concentrated compensation is lower than that of distributed compensation, a higher reduction in electrical losses and a lower payback period are obtained with distributed compensation. Although the lowest payback period was obtained with distributed compensation with capacitor banks (0.4 years), it is not recommended in the presence of harmonics because the effects of current harmonics significantly reduce the useful life of these elements. For this reason, distributed compensation with harmonic filters obtained a payback period of 0.6 years, and it was proposed as the best solution. These results should be considered in projects aimed at power factor compensation in IESs with harmonics. The concentrated compensation of the capacitor bank at the PCC is proposed because of the lower investment cost and ease of installation. However, the advantages of distributed compensation with harmonic filters have not been evaluated. An energy efficiency approach is used to analyze the impact of the location methods of the power factor compensation equipment on the electrical losses of the IES.

ElectricityVol. 5(3)
National Training Service (CO), Universidad Nacional de Colombia (CO), University of the Coast (CO), Aalborg University (DK)
Aalborg Universitet, Universidad Nacional de Colombia
Affordable and clean energy
Openalex Percentile: Top 14%
Power Quality and Harmonics
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.