Performance and damage assessment of fault-crossing road tunnel subjected to internal boiling liquid expanding vapor explosion (BLEVE)

Road tunnels constructed in complex rock strata may encounter unfavourable geological formations such as rock faults. Grouting into rock faults around road tunnels or installing flexible joints for tunnel structures have been widely used in engineering practice to improve the performance of fault-crossing road tunnels against static and seismic loads. However, flexible joints with low stiffness and likely low strength may be subjected to direct explosion loads and their performance in resisting blast loads has not been investigated. In this study, the resistance of a typical fault-crossing road tunnel to an internal Boiling Liquid Expansion Vapour Explosion (BLEVE) caused by the rupture of a 20 m 3 Liquified Petroleum Gas (LPG) tank is numerically investigated. The response and residual load-bearing capacity of the fault-crossing road tunnel with and without the grouting and rubber joints under the internal BLEVE are calculated and compared. It is found that the combined measures greatly enhance the BLEVE resistance of the fault-crossing road tunnel due to the fact that grouting greatly improves the mechanical properties of the fault-affected rock mass, and the rubber joints significantly attenuate the BLEVE-induced stress wave propagation inside the tunnel lining. In addition, parametric analyses are conducted to investigate the effects of the grouting and rubber joint configurations on the BLEVE resistance of the fault-crossing road tunnel. Damage criteria considering the tunnel’s residual load-bearing capacity (RLBC) are also established to evaluate the collapse risk and potential collapse zone of the fault-crossing road tunnel after being exposed to internal BLEVE. The results show that the potential collapse zones of the fault-crossing road tunnel along the longitudinal direction of the tunnel can be effectively reduced by increasing grouting thicknesses and installing narrower rubber joints.

Authors

Institutions

Publication Details

Journal
Tunnelling and Underground Space Technology
Published
2024-09-06
DOI
https://doi.org/10.1016/j.tust.2024.106056
Citations
3
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
3.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and damage assessment of fault-crossing road tunnel subjected to internal boiling liquid expanding vapor explosion (BLEVE)

Wensu Chen, Ruishan Cheng, Hong Shun Hao
3 citations
Tunnelling and Underground Space Technology
Combustion and Detonation Processes
3.90
article

Performance and damage assessment of fault-crossing road tunnel subjected to internal boiling liquid expanding vapor explosion (BLEVE)

Wensu Chen, Ruishan Cheng, Hong Shun Hao
article en
3 citations

Abstract

Road tunnels constructed in complex rock strata may encounter unfavourable geological formations such as rock faults. Grouting into rock faults around road tunnels or installing flexible joints for tunnel structures have been widely used in engineering practice to improve the performance of fault-crossing road tunnels against static and seismic loads. However, flexible joints with low stiffness and likely low strength may be subjected to direct explosion loads and their performance in resisting blast loads has not been investigated. In this study, the resistance of a typical fault-crossing road tunnel to an internal Boiling Liquid Expansion Vapour Explosion (BLEVE) caused by the rupture of a 20 m 3 Liquified Petroleum Gas (LPG) tank is numerically investigated. The response and residual load-bearing capacity of the fault-crossing road tunnel with and without the grouting and rubber joints under the internal BLEVE are calculated and compared. It is found that the combined measures greatly enhance the BLEVE resistance of the fault-crossing road tunnel due to the fact that grouting greatly improves the mechanical properties of the fault-affected rock mass, and the rubber joints significantly attenuate the BLEVE-induced stress wave propagation inside the tunnel lining. In addition, parametric analyses are conducted to investigate the effects of the grouting and rubber joint configurations on the BLEVE resistance of the fault-crossing road tunnel. Damage criteria considering the tunnel’s residual load-bearing capacity (RLBC) are also established to evaluate the collapse risk and potential collapse zone of the fault-crossing road tunnel after being exposed to internal BLEVE. The results show that the potential collapse zones of the fault-crossing road tunnel along the longitudinal direction of the tunnel can be effectively reduced by increasing grouting thicknesses and installing narrower rubber joints.

Tunnelling and Underground Space TechnologyVol. 154
Curtin University (AU), Guangzhou University (CN)
Australian Research Council
Sustainable cities and communities
Openalex Percentile: Top 6%
Combustion and Detonation Processes
3.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.