Patient's head position-dependent safety analysis of birdcage coil, loop array, and dipole array for applications at 300 MHz in magnetic resonance imaging based on hydrogen nuclei: Simulation study

The specific absorption rate (SAR) substantially contributes to the elevation of patient temperatures during magnetic resonance imaging (MRI) scans, potentially leading to tissue degeneration and damage. In particular, the relatively short wavelength of radio frequency (RF) used in ultra-high field (UHF)-MRI generates non-uniform RF excitation (|B 1 + |) and electric (|E|)-fields within the body, with the potential to cause localized increases in tissue temperature. This study employs electromagnetic (EM) simulations to quantitatively assesses variations in SAR resulting from different patient's head positions across three types of RF coils (birdcage coil, loop array coil, and dipole array coil), frequently employed as transmission/reception (Tx/Rx) coils in 7 T MRI. Through analysis of 715 SAR values per RF coil, achieved by varying patient's head positions at 5 mm intervals within the maximum range of movement, the study shows substantial changes in SAR values averaged over 10 g of tissue (SAR 10g ). Notably, these changes reach a maximum difference of 339.89 % and 371.13 % in comparison to the iso-center (no change), concerning global- and local-SAR 10g . Interestingly, the study identifies instances where SAR values surpass the standard SAR limit suggested by the safety guidelines, even when the distance between the RF coil and the patient exceeded 10 mm.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2024-09-06
DOI
https://doi.org/10.1016/j.net.2024.08.048
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient's head position-dependent safety analysis of birdcage coil, loop array, and dipole array for applications at 300 MHz in magnetic resonance imaging based on hydrogen nuclei: Simulation study

Taewoo Nam, E. Lee, Yeunchul Ryu, Daniel Hernandez et al.
Nuclear Engineering and Technology
Advanced MRI Techniques and Applications
article

Patient's head position-dependent safety analysis of birdcage coil, loop array, and dipole array for applications at 300 MHz in magnetic resonance imaging based on hydrogen nuclei: Simulation study

Taewoo Nam, E. Lee, Yeunchul Ryu, Daniel Hernandez, Donghyuk Kim, Kyoung‐Nam Kim, Yeji Han
article en

Abstract

The specific absorption rate (SAR) substantially contributes to the elevation of patient temperatures during magnetic resonance imaging (MRI) scans, potentially leading to tissue degeneration and damage. In particular, the relatively short wavelength of radio frequency (RF) used in ultra-high field (UHF)-MRI generates non-uniform RF excitation (|B 1 + |) and electric (|E|)-fields within the body, with the potential to cause localized increases in tissue temperature. This study employs electromagnetic (EM) simulations to quantitatively assesses variations in SAR resulting from different patient's head positions across three types of RF coils (birdcage coil, loop array coil, and dipole array coil), frequently employed as transmission/reception (Tx/Rx) coils in 7 T MRI. Through analysis of 715 SAR values per RF coil, achieved by varying patient's head positions at 5 mm intervals within the maximum range of movement, the study shows substantial changes in SAR values averaged over 10 g of tissue (SAR 10g ). Notably, these changes reach a maximum difference of 339.89 % and 371.13 % in comparison to the iso-center (no change), concerning global- and local-SAR 10g . Interestingly, the study identifies instances where SAR values surpass the standard SAR limit suggested by the safety guidelines, even when the distance between the RF coil and the patient exceeded 10 mm.

Nuclear Engineering and TechnologyVol. 57(2)
Gachon University (KR), University of Pittsburgh (US)
Affordable and clean energy
Openalex Percentile: Top 75%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.