Cardiac Pacemaker and the Effect on Hemodynamics of the Tricuspid Valve

Placement of ICDs, permanent pacemakers and biventricular devices is performed under fluoroscopic guidance. Implantable device leads can cause Tricuspid Regurgitation (TR) when they interfere with leaflet motion. In our clinical experience, we had two cases where patients with endocardial right ventricle leads developed severe TR. One patient was treated by having his leads repositioned and the other required surgery. This study analyzed the grade of tricuspid regurgitation before and after implantation of lead pacmencker in Right Ventrecle. Aim: Evaluation of tricuspid regurgitation after right ventricular permanent lead implantation to check if echocardiographic guidance is needed for adequate lead positioning. Methods: 76 patients had trans-thoracic Doppler echocardiographic studies before and after implantation of permanent right ventricular leads. Results: Before Right Ventricular (RV) lead implantation, 96% of patients had Tricuspid Regurgitation (TR). Patients were stratified by grade of regurgitation. 57 patients were grade 1 (75%), 12 (16%) were grade 2 and 4 were grade 3 or 4 (5%). After RV lead implantation, 44 patients with grade 1 TR remained with the same degree (77%) while in 2 (3.5%) TR progressed to grade 2 and in the remainder the TR disappeared. Most of the patients with grade 2 TR before RV lead implantation (75%) remained in grade 2 while 25% the grade decreased to grade 1. In all the patients with grade 3 and 4 TR pre-implantation, the severity of TR decreased by one grade. In 56 patients with non-CRT device implantations, 39 (70%) had grade 1 TR before procedure. After implantation, 28 (72%) of them did not change grade and 11 (28%) progressed to grade 2. Regarding grade 2 TR before implantation in 8 patients (14%) – the TR grade decreased in 3 (37.5%) and did not change in the others. In 3 (5.4%) patients with grade 3 and 4 TR before the procedure, the TR decreased after procedure. Conclusion: Implantation of permanent RV leads did not worsen TR grade.

Authors

Publication Details

Journal
Journal of Clinical Medical Research
Published
2024-09-06
DOI
https://doi.org/10.46889/jcmr.2024.5301
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac Pacemaker and the Effect on Hemodynamics of the Tricuspid Valve

Haydar Mohammad
Journal of Clinical Medical Research
Cardiac Valve Diseases and Treatments
article

Cardiac Pacemaker and the Effect on Hemodynamics of the Tricuspid Valve

Haydar Mohammad
article en

Abstract

Placement of ICDs, permanent pacemakers and biventricular devices is performed under fluoroscopic guidance. Implantable device leads can cause Tricuspid Regurgitation (TR) when they interfere with leaflet motion. In our clinical experience, we had two cases where patients with endocardial right ventricle leads developed severe TR. One patient was treated by having his leads repositioned and the other required surgery. This study analyzed the grade of tricuspid regurgitation before and after implantation of lead pacmencker in Right Ventrecle. Aim: Evaluation of tricuspid regurgitation after right ventricular permanent lead implantation to check if echocardiographic guidance is needed for adequate lead positioning. Methods: 76 patients had trans-thoracic Doppler echocardiographic studies before and after implantation of permanent right ventricular leads. Results: Before Right Ventricular (RV) lead implantation, 96% of patients had Tricuspid Regurgitation (TR). Patients were stratified by grade of regurgitation. 57 patients were grade 1 (75%), 12 (16%) were grade 2 and 4 were grade 3 or 4 (5%). After RV lead implantation, 44 patients with grade 1 TR remained with the same degree (77%) while in 2 (3.5%) TR progressed to grade 2 and in the remainder the TR disappeared. Most of the patients with grade 2 TR before RV lead implantation (75%) remained in grade 2 while 25% the grade decreased to grade 1. In all the patients with grade 3 and 4 TR pre-implantation, the severity of TR decreased by one grade. In 56 patients with non-CRT device implantations, 39 (70%) had grade 1 TR before procedure. After implantation, 28 (72%) of them did not change grade and 11 (28%) progressed to grade 2. Regarding grade 2 TR before implantation in 8 patients (14%) – the TR grade decreased in 3 (37.5%) and did not change in the others. In 3 (5.4%) patients with grade 3 and 4 TR before the procedure, the TR decreased after procedure. Conclusion: Implantation of permanent RV leads did not worsen TR grade.

Journal of Clinical Medical Research
Good health and well-being
Openalex Percentile: Top 73%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.