A portable lateral flow distance-based paper sensor for drinking water hardness test

Hardness is one of the basic parameters of water, and a high-level hardness of drinking water may be harmful to human health. Thus, it is very important to monitor drinking water hardness. In this work, a portable lateral flow distance-based paper sensor for the semi-quantitative detection of drinking water hardness is demonstrated. In the presence of Ca2+/Mg2+, the hydrogel can be formed via the chelation between sodium alginate and Ca2+/Mg2+, inducing a phase separation process. The viscosity change of the sodium alginate solution is directly related to the Ca2+/Mg2+ concentration and can be determined by the water lateral flow distance on test strips. The sensor successfully realizes the quantification of Ca2+ and Mg2+ in the range of 0-10 mmol L-1 and 4-20 mmol L-1, respectively. The recoveries are found varied from 95% to 108.9%. The water hardness is acceptable for drinking if the Cr values lies in the range of 0.259 to 0.419, and it is high with the Cr value above 0.595. Remarkably, the performance of the sensor is comparable with the commercial kit for real water samples, which avoids the subjective judgment. Overall, this method provides a portable approach for semi-quantitative detection of drinking water hardness with the merits of convenience and low cost, which shows great potential for the potential application.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-09-06
DOI
https://doi.org/10.1371/journal.pone.0308424
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A portable lateral flow distance-based paper sensor for drinking water hardness test

Yulin Liu, Wen‐Li Wu, Jiantao Ping, Qiongzheng Hu et al.
PLoS ONE
Biosensors and Analytical Detection
article

A portable lateral flow distance-based paper sensor for drinking water hardness test

Yulin Liu, Wen‐Li Wu, Jiantao Ping, Qiongzheng Hu, Longzhan Dong, Jingbo Chen
article en

Abstract

Hardness is one of the basic parameters of water, and a high-level hardness of drinking water may be harmful to human health. Thus, it is very important to monitor drinking water hardness. In this work, a portable lateral flow distance-based paper sensor for the semi-quantitative detection of drinking water hardness is demonstrated. In the presence of Ca2+/Mg2+, the hydrogel can be formed via the chelation between sodium alginate and Ca2+/Mg2+, inducing a phase separation process. The viscosity change of the sodium alginate solution is directly related to the Ca2+/Mg2+ concentration and can be determined by the water lateral flow distance on test strips. The sensor successfully realizes the quantification of Ca2+ and Mg2+ in the range of 0-10 mmol L-1 and 4-20 mmol L-1, respectively. The recoveries are found varied from 95% to 108.9%. The water hardness is acceptable for drinking if the Cr values lies in the range of 0.259 to 0.419, and it is high with the Cr value above 0.595. Remarkably, the performance of the sensor is comparable with the commercial kit for real water samples, which avoids the subjective judgment. Overall, this method provides a portable approach for semi-quantitative detection of drinking water hardness with the merits of convenience and low cost, which shows great potential for the potential application.

PLoS ONEVol. 19(9)
Qilu University of Technology (CN), Shandong Academy of Sciences (CN), Shandong First Medical University (CN)
Natural Science Foundation of Shandong Province, Taishan Scholar Foundation of Shandong Province, Qilu University of Technology
Clean water and sanitation
Openalex Percentile: Top 87%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A portable lateral flow distance-based paper sensor for drinking water hardness test — Yulin Liu, Wen‐Li Wu, et al. · PLoS ONE (2024) | TGRS Research Map | TGRS