Coherent photonic time stretch for ultrafast spectrum measurement

The paper presents an ultrafast spectrum measurement method based on photonic time stretching technology. The working principle of the photonic time stretch enhanced recording scheme is discussed. This scheme, based on the direct detection, have disadvantages such as loss of information about the phase of the modulated signal, high harmonic distortions due to the non-linear characteristic of the output signal due to the squaring of the electric field by photodetector. To avoid these disadvantages, the coherent photonic time stretch enhanced recording scheme is discussed. Further, this time stretching technology was designed in the VPIphotonics Design Suite software environment. Finally, based on the simulation, a graph of measurement error was constructed. The maximum error of the scheme is 180 MHz at the frequency before 5 GHz. After 5 GHz, the frequency measurement error less than 100 MHz and after 10 GHz, the frequency measurement error does not exceed 50 MHz.

Authors

Publication Details

Published
2024-09-06
DOI
https://doi.org/10.1117/12.3027191
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coherent photonic time stretch for ultrafast spectrum measurement

Oleg G. Morozov, Nikolay V. Petrov
Advanced Optical Sensing Technologies
article

Coherent photonic time stretch for ultrafast spectrum measurement

Oleg G. Morozov, Nikolay V. Petrov
article en

Abstract

The paper presents an ultrafast spectrum measurement method based on photonic time stretching technology. The working principle of the photonic time stretch enhanced recording scheme is discussed. This scheme, based on the direct detection, have disadvantages such as loss of information about the phase of the modulated signal, high harmonic distortions due to the non-linear characteristic of the output signal due to the squaring of the electric field by photodetector. To avoid these disadvantages, the coherent photonic time stretch enhanced recording scheme is discussed. Further, this time stretching technology was designed in the VPIphotonics Design Suite software environment. Finally, based on the simulation, a graph of measurement error was constructed. The maximum error of the scheme is 180 MHz at the frequency before 5 GHz. After 5 GHz, the frequency measurement error less than 100 MHz and after 10 GHz, the frequency measurement error does not exceed 50 MHz.

Affordable and clean energy
Openalex Percentile: Top 88%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Coherent photonic time stretch for ultrafast spectrum measurement — Oleg G. Morozov, Nikolay V. Petrov · (2024) | TGRS Research Map | TGRS