Compliance Analysis of Series Arc-fault in AFCI- Equipped Inverters in Accordance with IEC 63027

The National Institute of Metrology, Quality and Technology (Instituto Nacional de Metrologia, Qualidade e Tecnologia - INMETRO) introduces that, starting in 2024, all photovoltaic (PV) inverters sold in the Brazilian market must incorporate an Arc-Fault Circuit Interrupt (AFCI) function into their systems. These inverters are required to comply with the IEC 63027:2023 (Photovoltaic power systems DC arc detection and interruption) standard. Considering this, the Electrical Engineering Laboratory at Mackenzie Presbyterian University (Universidade Presbiteriana Mackenzie UPM) conducted a series of arc-faults tests on three inverters available in the market, following the IEC 63027 standard. Each of the three inverters underwent a total of 32 arcs, considering number of Maximum Power Point Tracking (MPPT) ports, different impedance topologies, arc position in the PV system, and maximum values of voltage and current. The experiments revealed that two of the three inverters are not capable of meeting the international standard for detecting and interrupting series arc-faults, highlighting the need evaluation of PV inverter sold in the Brazilian market. During the analysis, it was noted that for certain parameters proposed by IEC 63027, there is a gap of information regarding evaluation of the data relating to arc self-extinguish or actual AFCI intervention. It is show that this scenario can raise a concern: the possibility exists for an inverter meet the international standard without implementing an effective AFCI technology. The 96 tests conducted were compared in terms of arc detection time and arc energy. The data were analyzed and compared with respect to the phenomena of arc self-extinguishing and the operation of the AFCI. Suggestions for enhancements to the IEC 63027 standard were provided

Authors

Institutions

Publication Details

Journal
IEEE Latin America Transactions
Published
2024-09-01
DOI
https://doi.org/10.1109/tla.2024.10669358
Citations
5
Primary Topic
Risk and Safety Analysis
Type
article
Field-Weighted Citation Impact
2.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compliance Analysis of Series Arc-fault in AFCI- Equipped Inverters in Accordance with IEC 63027

José César de Souza Almeida Neto, Fábio Jesus Moreira de Almeida, Sílvia Maria Stortini González Velázquez, Bruno Luis Soares De Lima et al.
5 citations
IEEE Latin America Transactions
Risk and Safety Analysis
2.31
article

Compliance Analysis of Series Arc-fault in AFCI- Equipped Inverters in Accordance with IEC 63027

José César de Souza Almeida Neto, Fábio Jesus Moreira de Almeida, Sílvia Maria Stortini González Velázquez, Bruno Luis Soares De Lima, Filipe Figueiredo Ramos
article en
5 citations

Abstract

The National Institute of Metrology, Quality and Technology (Instituto Nacional de Metrologia, Qualidade e Tecnologia - INMETRO) introduces that, starting in 2024, all photovoltaic (PV) inverters sold in the Brazilian market must incorporate an Arc-Fault Circuit Interrupt (AFCI) function into their systems. These inverters are required to comply with the IEC 63027:2023 (Photovoltaic power systems DC arc detection and interruption) standard. Considering this, the Electrical Engineering Laboratory at Mackenzie Presbyterian University (Universidade Presbiteriana Mackenzie UPM) conducted a series of arc-faults tests on three inverters available in the market, following the IEC 63027 standard. Each of the three inverters underwent a total of 32 arcs, considering number of Maximum Power Point Tracking (MPPT) ports, different impedance topologies, arc position in the PV system, and maximum values of voltage and current. The experiments revealed that two of the three inverters are not capable of meeting the international standard for detecting and interrupting series arc-faults, highlighting the need evaluation of PV inverter sold in the Brazilian market. During the analysis, it was noted that for certain parameters proposed by IEC 63027, there is a gap of information regarding evaluation of the data relating to arc self-extinguish or actual AFCI intervention. It is show that this scenario can raise a concern: the possibility exists for an inverter meet the international standard without implementing an effective AFCI technology. The 96 tests conducted were compared in terms of arc detection time and arc energy. The data were analyzed and compared with respect to the phenomena of arc self-extinguishing and the operation of the AFCI. Suggestions for enhancements to the IEC 63027 standard were provided

IEEE Latin America TransactionsVol. 22(9)
Universidade Presbiteriana Mackenzie (BR)
Openalex Percentile: Top 11%
Risk and Safety Analysis
2.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.