Deep learning–based statistical robustness evaluation of intensity-modulated proton therapy for head and neck cancer

<i>Objective</i>. Previous methods for robustness evaluation rely on dose calculation for a number of uncertainty scenarios, which either fails to provide statistical meaning when the number is too small (e.g., ∼8) or becomes unfeasible in daily clinical practice when the number is sufficiently large (e.g., >100). Our proposed deep learning (DL)-based method addressed this issue by avoiding the intermediate dose calculation step and instead directly predicting the percentile dose distribution from the nominal dose distribution using a DL model. In this study, we sought to validate this DL-based statistical robustness evaluation method for efficient and accurate robustness quantification in head and neck (H&N) intensity-modulated proton therapy with diverse beam configurations and multifield optimization.<i>Approach</i>. A dense, dilated 3D U-net was trained to predict the 5th and 95th percentile dose distributions of uncertainty scenarios using the nominal dose and planning CT images. The data set comprised proton therapy plans for 582 H&N cancer patients. Ground truth percentile values were estimated for each patient through 600 dose recalculations, representing randomly sampled uncertainty scenarios. The comprehensive comparisons of different models were conducted for H&N cancer patients, considering those with and without a beam mask and diverse beam configurations, including varying beam angles, couch angles, and beam numbers. The performance of our model trained based on a mixture of patients with H&N and prostate cancer was also assessed in contrast with models trained based on data specific for patients with cancer at either site.<i>Results</i>. The DL-based model's predictions of percentile dose distributions exhibited excellent agreement with the ground truth dose distributions. The average gamma index with 2 mm<i>/</i>2%, consistently exceeded 97% for both 5th and 95th percentile dose volumes. Mean dose-volume histogram error analysis revealed that predictions from the combined training set yielded mean errors and standard deviations that were generally similar to those in the specific patient training data sets.<i>Significance</i>. Our proposed DL-based method for evaluation of the robustness of proton therapy plans provides precise, rapid predictions of percentile dose for a given confidence level regardless of the beam arrangement and cancer site. This versatility positions our model as a valuable tool for evaluating the robustness of proton therapy across various cancer sites.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-09-06
DOI
https://doi.org/10.1088/1361-6560/ad780b
Citations
1
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning–based statistical robustness evaluation of intensity-modulated proton therapy for head and neck cancer

Steven Jay Frank, Ivan Vazquez, X Zhu, Laurence E. Court et al.
1 citations
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
0.42
article

Deep learning–based statistical robustness evaluation of intensity-modulated proton therapy for head and neck cancer

Steven Jay Frank, Ivan Vazquez, X Zhu, Laurence E. Court, Ming Yang, Mary Gronberg, Xiaodong Zhang, D. T. W. Liang, Mary K. Martel
article en
1 citations

Abstract

<i>Objective</i>. Previous methods for robustness evaluation rely on dose calculation for a number of uncertainty scenarios, which either fails to provide statistical meaning when the number is too small (e.g., ∼8) or becomes unfeasible in daily clinical practice when the number is sufficiently large (e.g., >100). Our proposed deep learning (DL)-based method addressed this issue by avoiding the intermediate dose calculation step and instead directly predicting the percentile dose distribution from the nominal dose distribution using a DL model. In this study, we sought to validate this DL-based statistical robustness evaluation method for efficient and accurate robustness quantification in head and neck (H&N) intensity-modulated proton therapy with diverse beam configurations and multifield optimization.<i>Approach</i>. A dense, dilated 3D U-net was trained to predict the 5th and 95th percentile dose distributions of uncertainty scenarios using the nominal dose and planning CT images. The data set comprised proton therapy plans for 582 H&N cancer patients. Ground truth percentile values were estimated for each patient through 600 dose recalculations, representing randomly sampled uncertainty scenarios. The comprehensive comparisons of different models were conducted for H&N cancer patients, considering those with and without a beam mask and diverse beam configurations, including varying beam angles, couch angles, and beam numbers. The performance of our model trained based on a mixture of patients with H&N and prostate cancer was also assessed in contrast with models trained based on data specific for patients with cancer at either site.<i>Results</i>. The DL-based model's predictions of percentile dose distributions exhibited excellent agreement with the ground truth dose distributions. The average gamma index with 2 mm<i>/</i>2%, consistently exceeded 97% for both 5th and 95th percentile dose volumes. Mean dose-volume histogram error analysis revealed that predictions from the combined training set yielded mean errors and standard deviations that were generally similar to those in the specific patient training data sets.<i>Significance</i>. Our proposed DL-based method for evaluation of the robustness of proton therapy plans provides precise, rapid predictions of percentile dose for a given confidence level regardless of the beam arrangement and cancer site. This versatility positions our model as a valuable tool for evaluating the robustness of proton therapy across various cancer sites.

Physics in Medicine and BiologyVol. 69(19)
The University of Texas MD Anderson Cancer Center (US), The University of Texas Southwestern Medical Center (US), The University of Texas Health Science Center at Houston (US)
Cancer Prevention and Research Institute of Texas
Good health and well-being
Openalex Percentile: Top 33%
Radiation Therapy and Dosimetry
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.