Evaluation of a solar-driven adsorption desalination system for Brazilian semiarid region

In this study, the effect of using a hybrid solar thermal-activated adsorption desalination system for brackish water is evaluated under the climatic conditions of the Brazilian semiarid region. The proposed theoretical model utilizes climatic data from the meteorological station in Campina Grande, PB, and adsorptive kinetics data of Fuji Davison RD 260 silica gel to predict the performance indices of the specific daily water production (SDWP), specific cooling power (SCP), and coefficient of performance (COP) performance coefficients over a characteristic day. The SDWP value of 6.26 m3/ton, SCP ranging from 50 to 300 W/kg, and an average COP of 0.5 were obtained, considering variations in global horizontal irradiance in the ACDS system and transient ambient temperature. It was observed that both the production of desalinated water and the refrigeration effect increase with the rise in daily solar irradiance. The variation in the number of solar collectors used in the system and their optimality, as well as the variation in the salinity index of the feed source, impacted the evaluated performance coefficients.

Authors

Institutions

Publication Details

Journal
Applied Water Science
Published
2024-09-05
DOI
https://doi.org/10.1007/s13201-024-02265-5
Citations
5
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
1.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a solar-driven adsorption desalination system for Brazilian semiarid region

Mário Benjamim Baptista de Siqueira, Roberto C. Marçal
5 citations
Applied Water Science
Adsorption and Cooling Systems
1.06
article

Evaluation of a solar-driven adsorption desalination system for Brazilian semiarid region

Mário Benjamim Baptista de Siqueira, Roberto C. Marçal
article en
5 citations

Abstract

In this study, the effect of using a hybrid solar thermal-activated adsorption desalination system for brackish water is evaluated under the climatic conditions of the Brazilian semiarid region. The proposed theoretical model utilizes climatic data from the meteorological station in Campina Grande, PB, and adsorptive kinetics data of Fuji Davison RD 260 silica gel to predict the performance indices of the specific daily water production (SDWP), specific cooling power (SCP), and coefficient of performance (COP) performance coefficients over a characteristic day. The SDWP value of 6.26 m3/ton, SCP ranging from 50 to 300 W/kg, and an average COP of 0.5 were obtained, considering variations in global horizontal irradiance in the ACDS system and transient ambient temperature. It was observed that both the production of desalinated water and the refrigeration effect increase with the rise in daily solar irradiance. The variation in the number of solar collectors used in the system and their optimality, as well as the variation in the salinity index of the feed source, impacted the evaluated performance coefficients.

Applied Water ScienceVol. 14(10)
Universidade de Brasília (BR)
Climate action
Openalex Percentile: Top 26%
Adsorption and Cooling Systems
1.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.