A novel thiourea‐based fluorescent turn‐on sensor for rapidly detecting hypochlorite through a desulfurization reaction

Abstract Excess hypochlorite (ClO − ) is harmful to living organisms and can cause various oxidative diseases in the human body. Owing to the toxicity of ClO − , the development of efficient fluorescence sensors to track ClO − is necessary. In this work, we report a novel thiourea‐based fluorescent turn‐on sensor 1‐(9‐ethyl‐9 H ‐carbazol‐3‐yl)‐3‐(naphthalen‐1‐yl)thiourea ( ECNT ) for recognizing ClO − . ECNT can detect ClO − with high selectivity, relatively low interference with other analytes, and a significantly fast response time (<1 s) through a desulfurization reaction. The detection limit of ECNT for ClO − is calculated as 5.59 μM. Of note, ECNT is a chemosensor that reacts the fastest with ClO − among the reported thiourea‐based fluorescence turn‐on sensors for detecting ClO − . The response mechanism of ECNT to ClO − is demonstrated through 1 H NMR titration, ESI mass, and density functional theory calculations.

Authors

Institutions

Publication Details

Journal
Bulletin of the Korean Chemical Society
Published
2024-09-01
DOI
https://doi.org/10.1002/bkcs.12897
Citations
2
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel thiourea‐based fluorescent turn‐on sensor for rapidly detecting hypochlorite through a desulfurization reaction

Boeun Choi, Cheal Kim, Soyeon Kim
2 citations
Bulletin of the Korean Chemical Society
Molecular Sensors and Ion Detection
0.48
article

A novel thiourea‐based fluorescent turn‐on sensor for rapidly detecting hypochlorite through a desulfurization reaction

Boeun Choi, Cheal Kim, Soyeon Kim
article en
2 citations

Abstract

Abstract Excess hypochlorite (ClO − ) is harmful to living organisms and can cause various oxidative diseases in the human body. Owing to the toxicity of ClO − , the development of efficient fluorescence sensors to track ClO − is necessary. In this work, we report a novel thiourea‐based fluorescent turn‐on sensor 1‐(9‐ethyl‐9 H ‐carbazol‐3‐yl)‐3‐(naphthalen‐1‐yl)thiourea ( ECNT ) for recognizing ClO − . ECNT can detect ClO − with high selectivity, relatively low interference with other analytes, and a significantly fast response time (<1 s) through a desulfurization reaction. The detection limit of ECNT for ClO − is calculated as 5.59 μM. Of note, ECNT is a chemosensor that reacts the fastest with ClO − among the reported thiourea‐based fluorescence turn‐on sensors for detecting ClO − . The response mechanism of ECNT to ClO − is demonstrated through 1 H NMR titration, ESI mass, and density functional theory calculations.

Bulletin of the Korean Chemical SocietyVol. 45(9)
Seoul National University of Science and Technology (KR)
National Research Foundation of Korea
Openalex Percentile: Top 41%
Molecular Sensors and Ion Detection
0.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.