Use of Threshold Median Adjustment to Achieve Accurate Current Balancing of Interleaved Buck Converter with Constant Frequency Hysteresis Control
This paper proposes a current balancing loop that is obtained using the threshold median adjustment (TMA-CBL) to achieve the accurate current balancing of an interleaved constant frequency hysteresis (CFH) buck converter. The CFH control is implemented with a frequency phase loop based on a threshold width adjustment (TWA-FPL). To ensure the loop’s stability and minimize the steady-state error, a multi-phase, coupled, small-signal model (MPC-SSM) is derived with a consideration of the coupling effect among the multiple phases. Furthermore, the current balancing error is analyzed in detail, with a consideration of the sensing resistance deviations in the loop. Finally, based on a 180 nm BCD process, a four-phase interleaved buck converter is fabricated to verify the effectiveness of the proposed TMA-CBL. The maximum current balancing error is within 0.68% when the sensing resistors are deviated by 5%.
Authors
- Yuxiang Yang (ORCID: https://orcid.org/0000-0002-4750-7293)
- Liangliang Lu (ORCID: https://orcid.org/0000-0002-7053-9314)
- Desheng Zhang (ORCID: https://orcid.org/0000-0001-9174-8011)
- Yuchao Huang
- Qidong Li (ORCID: https://orcid.org/0000-0001-7712-2848)
- Zeli Li
Institutions
- Wuhan University of Technology (CN)
- Huazhong University of Science and Technology (CN)
Publication Details
- Journal
- Electronics
- Published
- 2024-09-04
- DOI
- https://doi.org/10.3390/electronics13173521
- Citations
- 1
- Primary Topic
- Advanced DC-DC Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.21