Experimental assessment of diffusible iodine-based contrast-enhanced computed tomography (diceCT) protocols

Diffusible iodine-based contrast-enhanced computed tomography (diceCT) is an increasingly used digital complement, supplement, or alternative to traditional dissection-based anatomical research. The diceCT protocol, which has evolved and expanded over the past decade, employs passive diffusion of Lugol's iodine (KI<sub>3</sub>) to increase soft tissue radiodensity and improve structure contrast in the CT or microCT imaging of specimens. The development and application of diceCT has focused largely on specimens under 1 kg, and the varying reporting of methods on studies of both small and large specimens has initiated, but not yet established, an effective diceCT protocol for larger specimens based on monitored experiments of several fundamental variables (<i>e.g</i>., Lugol's iodine concentration, duration, and impacts of Lugol's iodine on tissues). In this study, we have experimentally assessed the efficacy of diceCT protocols for imaging whole-body specimens of the 1-4.5 kg Australian brushtail possum (<i>Trichosurus vulpecula</i>) using sequential CT imaging assessment across experimental conditions. We assessed the impact of varying Lugol's iodine concentration, the presence/absence of skin, solution volume and agitation on tissue radiodensity changes through weekly CT-based monitoring of tissue radiodensities over an 8-week experimental period. We have also quantified tissue volumetric changes across our experiment to assess the impact of diceCT applications on subsequent analyses of imaging datasets. Our results indicate that substantial changes in both soft-tissue radiodensity and soft-tissue volume occur within the first 28 days of Lugol's iodine treatment, followed by a slower rate of progressive soft-tissue radiodensity and volume changes across the experiment duration. Our results demonstrate the negligible benefit of skinning larger specimens to improve solution diffusion, and document significant soft-tissue volumetric changes with high concentration solutions (<i>e.g</i>., 10%) and long-duration exposure (<i>e.g</i>., beyond 5 weeks) that should guide individual diceCT protocol design and/or quantification and analysis for mammal specimens above 1 kg.

Authors

Institutions

Publication Details

Journal
PeerJ
Published
2024-09-05
DOI
https://doi.org/10.7717/peerj.17919
Citations
4
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental assessment of diffusible iodine-based contrast-enhanced computed tomography (diceCT) protocols

Justin W. Adams, Hazel L. Richards, Alistair R. Evans, Lucy Costello
4 citations
PeerJ
Advanced X-ray and CT Imaging
0.74
article

Experimental assessment of diffusible iodine-based contrast-enhanced computed tomography (diceCT) protocols

Justin W. Adams, Hazel L. Richards, Alistair R. Evans, Lucy Costello
article en
4 citations

Abstract

Diffusible iodine-based contrast-enhanced computed tomography (diceCT) is an increasingly used digital complement, supplement, or alternative to traditional dissection-based anatomical research. The diceCT protocol, which has evolved and expanded over the past decade, employs passive diffusion of Lugol's iodine (KI<sub>3</sub>) to increase soft tissue radiodensity and improve structure contrast in the CT or microCT imaging of specimens. The development and application of diceCT has focused largely on specimens under 1 kg, and the varying reporting of methods on studies of both small and large specimens has initiated, but not yet established, an effective diceCT protocol for larger specimens based on monitored experiments of several fundamental variables (<i>e.g</i>., Lugol's iodine concentration, duration, and impacts of Lugol's iodine on tissues). In this study, we have experimentally assessed the efficacy of diceCT protocols for imaging whole-body specimens of the 1-4.5 kg Australian brushtail possum (<i>Trichosurus vulpecula</i>) using sequential CT imaging assessment across experimental conditions. We assessed the impact of varying Lugol's iodine concentration, the presence/absence of skin, solution volume and agitation on tissue radiodensity changes through weekly CT-based monitoring of tissue radiodensities over an 8-week experimental period. We have also quantified tissue volumetric changes across our experiment to assess the impact of diceCT applications on subsequent analyses of imaging datasets. Our results indicate that substantial changes in both soft-tissue radiodensity and soft-tissue volume occur within the first 28 days of Lugol's iodine treatment, followed by a slower rate of progressive soft-tissue radiodensity and volume changes across the experiment duration. Our results demonstrate the negligible benefit of skinning larger specimens to improve solution diffusion, and document significant soft-tissue volumetric changes with high concentration solutions (<i>e.g</i>., 10%) and long-duration exposure (<i>e.g</i>., beyond 5 weeks) that should guide individual diceCT protocol design and/or quantification and analysis for mammal specimens above 1 kg.

PeerJVol. 12
Museums Victoria (AU), Monash University (AU)
National Imaging Facility, Monash University
Openalex Percentile: Top 32%
Advanced X-ray and CT Imaging
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.