Machine Learning Regressors to Estimate Continuous Oxygen Uptakes (V˙O2)

Oxygen consumption (V˙O2) estimation is vital for evaluating aerobic performance and cardiovascular fitness. This study explores various regression models to develop a real-time V˙O2 and V˙O2max estimation model. Utilizing a dataset from PhysioNet, encompassing cardiorespiratory measurements from 992 treadmill tests conducted at the University of Malaga’s Exercise Physiology and Human Performance Lab from 2008 to 2018, participants aged 10 to 63, including amateur and professional athletes, underwent breath-by-breath monitoring of physiological parameters. The study underlines the efficacy of regressor models in handling complex datasets and developing a robust real-time V˙O2 estimation model. After adjusting parameters to V˙O2 in “mL/kg/min” from “mL/min”, and selecting ‘Age’, ‘Weight’, ‘Height’, ‘HR’, ‘Sex’, and ‘Time’ as parameters for V˙O2 estimation, XGBoost emerged as the optimal choice. Validation using a test dataset of 132 participants yielded the following results for Mean Absolute Error (MAE), Mean Squared Error (MSE), Root Mean Squared Error (RMSE), R-squared (R2), Root Mean Squared Logarithmic Error (RMSLE), and Mean Absolute Percentage Error (MAPE) metrics: MAE of 0.1793, MSE of 0.1460, RMSE of 0.3821, R2 of 0.9991, RMSLE of 0.0140, and MAPE of 0.0066. This study demonstrates the effectiveness of various regressor models in developing a continuous V˙O2max estimation model that has promising performance metrics.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-09-05
DOI
https://doi.org/10.3390/app14177888
Citations
3
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
1.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine Learning Regressors to Estimate Continuous Oxygen Uptakes (V˙O2)

Sukkyu Sun, D. Y. Hong
3 citations
Applied Sciences
Hemodynamic Monitoring and Therapy
1.72
article

Machine Learning Regressors to Estimate Continuous Oxygen Uptakes (V˙O2)

Sukkyu Sun, D. Y. Hong
article en
3 citations

Abstract

Oxygen consumption (V˙O2) estimation is vital for evaluating aerobic performance and cardiovascular fitness. This study explores various regression models to develop a real-time V˙O2 and V˙O2max estimation model. Utilizing a dataset from PhysioNet, encompassing cardiorespiratory measurements from 992 treadmill tests conducted at the University of Malaga’s Exercise Physiology and Human Performance Lab from 2008 to 2018, participants aged 10 to 63, including amateur and professional athletes, underwent breath-by-breath monitoring of physiological parameters. The study underlines the efficacy of regressor models in handling complex datasets and developing a robust real-time V˙O2 estimation model. After adjusting parameters to V˙O2 in “mL/kg/min” from “mL/min”, and selecting ‘Age’, ‘Weight’, ‘Height’, ‘HR’, ‘Sex’, and ‘Time’ as parameters for V˙O2 estimation, XGBoost emerged as the optimal choice. Validation using a test dataset of 132 participants yielded the following results for Mean Absolute Error (MAE), Mean Squared Error (MSE), Root Mean Squared Error (RMSE), R-squared (R2), Root Mean Squared Logarithmic Error (RMSLE), and Mean Absolute Percentage Error (MAPE) metrics: MAE of 0.1793, MSE of 0.1460, RMSE of 0.3821, R2 of 0.9991, RMSLE of 0.0140, and MAPE of 0.0066. This study demonstrates the effectiveness of various regressor models in developing a continuous V˙O2max estimation model that has promising performance metrics.

Applied SciencesVol. 14(17)
Seoul National University (KR), Dongguk University (KR)
Good health and well-being
Openalex Percentile: Top 15%
Hemodynamic Monitoring and Therapy
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.