Application of Bi/PEDOT composite modified electrode in high-performance Cd (II) detection sensor

In this paper, Bismuth/poly(3,4-ethylenedioxythiophene) (Bi/PEDOT) modified electrochemical modified electrodes were prepared by electrochemical deposition method, and the electrochemical performance of the electrode was investigated using cyclic voltammetry under the optimal experimental conditions. The PEDOT polymer has high conductivity, and bismuth can form an alloy with cadmium ions. Bi/PEDOT nanocomposite materials have a larger specific surface area and more active sites, which is more conducive to absorbing more cadmium ions (Cd 2+ ). The Differential pulse anodic stripping voltammetry method was used to study the electroanalytical performance of the sensor for Cd 2+ . The data show that the oxidation peak current of cadmium ions in the Bi/PEDOT modified electrode is significantly higher than that of other electrodes, due to the synergistic effect of the composite conductive materials. In the concentration range of 1 nM-40 μM, the concentration of cadmium ions shows a good linear relationship with the peak current, and the lowest detection limit is 0.33 nM. In addition, the sensor also exhibits good stability, reproducibility and very low detection limit, which can be used for rapid determination of trace cadmium ions, with a recovery rate in actual sample analysis of 101.4 %-104.0 %.

Authors

Institutions

Publication Details

Journal
International Journal of Electrochemical Science
Published
2024-09-05
DOI
https://doi.org/10.1016/j.ijoes.2024.100780
Citations
3
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Bi/PEDOT composite modified electrode in high-performance Cd (II) detection sensor

Yijing Ai, Lin Yang, Lisi Wang, Xiaoping Zhang et al.
3 citations
International Journal of Electrochemical Science
Electrochemical Analysis and Applications
0.52
article

Application of Bi/PEDOT composite modified electrode in high-performance Cd (II) detection sensor

Yijing Ai, Lin Yang, Lisi Wang, Xiaoping Zhang, Wei Sun, Shihui Xu
article en
3 citations

Abstract

In this paper, Bismuth/poly(3,4-ethylenedioxythiophene) (Bi/PEDOT) modified electrochemical modified electrodes were prepared by electrochemical deposition method, and the electrochemical performance of the electrode was investigated using cyclic voltammetry under the optimal experimental conditions. The PEDOT polymer has high conductivity, and bismuth can form an alloy with cadmium ions. Bi/PEDOT nanocomposite materials have a larger specific surface area and more active sites, which is more conducive to absorbing more cadmium ions (Cd 2+ ). The Differential pulse anodic stripping voltammetry method was used to study the electroanalytical performance of the sensor for Cd 2+ . The data show that the oxidation peak current of cadmium ions in the Bi/PEDOT modified electrode is significantly higher than that of other electrodes, due to the synergistic effect of the composite conductive materials. In the concentration range of 1 nM-40 μM, the concentration of cadmium ions shows a good linear relationship with the peak current, and the lowest detection limit is 0.33 nM. In addition, the sensor also exhibits good stability, reproducibility and very low detection limit, which can be used for rapid determination of trace cadmium ions, with a recovery rate in actual sample analysis of 101.4 %-104.0 %.

International Journal of Electrochemical ScienceVol. 19(10)
Hainan Normal University (CN)
Affordable and clean energy
Openalex Percentile: Top 43%
Electrochemical Analysis and Applications
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of Bi/PEDOT composite modified electrode in high-performance Cd (II) detection sensor — Yijing Ai, Lin Yang, et al. · International Journal of Electrochemical Science (2024) | TGRS Research Map | TGRS