Development, evaluation of critical method variables and stability assessment using a Box–Behnken design for the determination of organic impurities in a pharmaceutical dosage form of a centrally acting muscle relaxant drug chlorzoxazone

This study validates a stability-indicating LC method for detecting organic impurities in the chlorzoxazone dosage form. Using a Waters X-Select R HSS T3 analytical column, mobile phase of it was made by mixing of water, methanol, and glacial acetic acid in the ratio of 700:300:10 (v/v/v). The drug product and drug substance were subjected to the stress conditions such as acid, base, oxidation, heat, and photolysis as per the recommendations of the International Conference on Harmonization (Q2) methodology. The study revealed the susceptibility of 4-chloro-2-aminophenol to alkaline environments, emphasizing peak homogeneity and stability. The method verification, per ICH guidelines and USP<1225>, established precision, specificity, linearity, accuracy, and robustness for quality control. The mean impurity recovery ranged from 95.5% to 105.2%, the correlation coefficient (r) was greater than 1.000, and the RSD values (n = 6) ranged from 0.6% to 5.1% across the LOQ-150% ranges. Full-factorial design tested final method conditions, evaluating multiple parameters concurrently. Graphical optimization within the design space defined strong method requirements, ensuring consistent and reliable outcomes. The study develops and validates chlorzoxazone stability-indicating methods, employing advanced statistical approaches like design of experiments and factorial design, with resilient conditions established through graphical optimization of the design space.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2024-09-04
DOI
https://doi.org/10.1002/bmc.6001
Citations
22
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
5.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development, evaluation of critical method variables and stability assessment using a Box–Behnken design for the determination of organic impurities in a pharmaceutical dosage form of a centrally acting muscle relaxant drug chlorzoxazone

Santhosh Kumar Ettaboina, Nagalakshmi Jeedimalla, Naresh Kumar Katari, Satyasree Nannapaneni et al.
22 citations
Biomedical Chromatography
Analytical Methods in Pharmaceuticals
5.19
article

Development, evaluation of critical method variables and stability assessment using a Box–Behnken design for the determination of organic impurities in a pharmaceutical dosage form of a centrally acting muscle relaxant drug chlorzoxazone

Santhosh Kumar Ettaboina, Nagalakshmi Jeedimalla, Naresh Kumar Katari, Satyasree Nannapaneni, Thirupathi Dongala, Siva Krishna Muchakayala
article en
22 citations

Abstract

This study validates a stability-indicating LC method for detecting organic impurities in the chlorzoxazone dosage form. Using a Waters X-Select R HSS T3 analytical column, mobile phase of it was made by mixing of water, methanol, and glacial acetic acid in the ratio of 700:300:10 (v/v/v). The drug product and drug substance were subjected to the stress conditions such as acid, base, oxidation, heat, and photolysis as per the recommendations of the International Conference on Harmonization (Q2) methodology. The study revealed the susceptibility of 4-chloro-2-aminophenol to alkaline environments, emphasizing peak homogeneity and stability. The method verification, per ICH guidelines and USP<1225>, established precision, specificity, linearity, accuracy, and robustness for quality control. The mean impurity recovery ranged from 95.5% to 105.2%, the correlation coefficient (r) was greater than 1.000, and the RSD values (n = 6) ranged from 0.6% to 5.1% across the LOQ-150% ranges. Full-factorial design tested final method conditions, evaluating multiple parameters concurrently. Graphical optimization within the design space defined strong method requirements, ensuring consistent and reliable outcomes. The study develops and validates chlorzoxazone stability-indicating methods, employing advanced statistical approaches like design of experiments and factorial design, with resilient conditions established through graphical optimization of the design space.

Biomedical ChromatographyVol. 38(11)
Agilent Technologies (United States) (US), Vignan's Foundation for Science, Technology & Research (IN), Catalent (United States) (US), GITAM University (IN), University of KwaZulu-Natal (ZA)
Clean water and sanitation
Openalex Percentile: Top 3%
Analytical Methods in Pharmaceuticals
5.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.