Numerical simulation of spray cooling heat transfer evolution based on experimental data

Spray cooling is an effective solution for high heat flux dissipation challenges. Accurate prediction of heat transfer efficiency by numerical simulation can reduce the cost of spray cooling in engineering applications. To improve the accuracy of numerical simulation, this study develops a mathematical model for droplet collision and heat transfer response based on experimental data. In spray cooling experiments, droplets are sprayed onto a 200 °C aluminum alloy thermal wall using an atomizing nozzle, temperature is monitored, and the curve of heat flux variation during cooling is estimated from temperature data. Analysis of high-speed photography results provides the droplet diameter, velocity, and spatial distribution. We discover that the average Weber number of droplets, We, has a power-law relationship with the volumetric flow rate, Q, as We ∼ Q1.55. The velocity and position of spray droplets approximately follow a normal distribution, while the diameter follows a Log-normal distribution. By analyzing the relation between heat flux and spray distribution, an experimental-data-based model, named Droplet Collision-Associated Heat Transfer Model, is designed. Integrating this experimental-data-based model with the discrete phase model (DPM), the heat transfer evolution process in spray cooling is simulated with high reliability. Particles sources are generated based on the experimentally obtained droplet parameter probability distributions, DPM is used to capture the trajectories of droplets, and the droplet impact heat transfer correlation model calculates the thermal response of the wall. Compared with experimental results, the simulation error is only 7.49%. Simulation results indicate that spray cooling at high flow rates has better temperature uniformity.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2024-09-01
DOI
https://doi.org/10.1063/5.0223935
Citations
9
Primary Topic
Fluid Dynamics and Heat Transfer
Type
article
Field-Weighted Citation Impact
3.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical simulation of spray cooling heat transfer evolution based on experimental data

Longsheng Duan, Di Wu, Jia Wang, Feng Shen et al.
9 citations
Physics of Fluids
Fluid Dynamics and Heat Transfer
3.37
article

Numerical simulation of spray cooling heat transfer evolution based on experimental data

Longsheng Duan, Di Wu, Jia Wang, Feng Shen, Li Duan, Qi Kang, Xin Yang
article en
9 citations

Abstract

Spray cooling is an effective solution for high heat flux dissipation challenges. Accurate prediction of heat transfer efficiency by numerical simulation can reduce the cost of spray cooling in engineering applications. To improve the accuracy of numerical simulation, this study develops a mathematical model for droplet collision and heat transfer response based on experimental data. In spray cooling experiments, droplets are sprayed onto a 200 °C aluminum alloy thermal wall using an atomizing nozzle, temperature is monitored, and the curve of heat flux variation during cooling is estimated from temperature data. Analysis of high-speed photography results provides the droplet diameter, velocity, and spatial distribution. We discover that the average Weber number of droplets, We, has a power-law relationship with the volumetric flow rate, Q, as We ∼ Q1.55. The velocity and position of spray droplets approximately follow a normal distribution, while the diameter follows a Log-normal distribution. By analyzing the relation between heat flux and spray distribution, an experimental-data-based model, named Droplet Collision-Associated Heat Transfer Model, is designed. Integrating this experimental-data-based model with the discrete phase model (DPM), the heat transfer evolution process in spray cooling is simulated with high reliability. Particles sources are generated based on the experimentally obtained droplet parameter probability distributions, DPM is used to capture the trajectories of droplets, and the droplet impact heat transfer correlation model calculates the thermal response of the wall. Compared with experimental results, the simulation error is only 7.49%. Simulation results indicate that spray cooling at high flow rates has better temperature uniformity.

Physics of FluidsVol. 36(9)
Chinese Academy of Sciences (CN), Beijing University of Technology (CN), Institute of Mechanics (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 7%
Fluid Dynamics and Heat Transfer
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.