DMD and microlens array as a switchable module for illumination angle scanning in optical diffraction tomography

Optical diffraction tomography (ODT) enables label-free and morphological 3D imaging of biological samples using refractive-index (RI) contrast. To accomplish this, ODT systems typically capture multiple angular-specific scattering measurements, which are used to computationally reconstruct a sample's 3D RI. Standard ODT systems employ scanning mirrors to generate angular illuminations. However, scanning mirrors are limited to illuminating the sample from only one angle at a time. Furthermore, when operated at high speeds, these mirrors may exhibit mechanical instabilities that compromise image quality and measurement speed. Recently, newer ODT systems have been introduced that utilize digital-micromirror devices (DMD), spatial light modulators (SLMs), or LED arrays to achieve switchable angle-scanning with no physically-scanning components. However, these systems associate with power inefficiencies and/or spurious diffraction orders that can also limit imaging performance. In this work, we developed a novel non-interferometric ODT system that utilizes a fully switchable module for angle scanning composed of a DMD and microlens array (MLA). Compared to other switchable ODT systems, this module enables each illumination angle to be generated fully independently from every other illumination angle (i.e., no spurious diffraction orders) while also optimizing the power efficiency based on the required density of illumination angles. We validate the quantitative imaging capability of this system using calibration microspheres. We also demonstrate its capability for imaging multiple-scattering samples by imaging an early-stage zebrafish embryo.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-09-05
DOI
https://doi.org/10.1364/boe.535123
Citations
14
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
4.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DMD and microlens array as a switchable module for illumination angle scanning in optical diffraction tomography

Mary E. Swartz, Johann K. Eberhart, Shwetadwip Chowdhury, Jeongsoo Kim et al.
14 citations
Biomedical Optics Express
Digital Holography and Microscopy
4.73
article

DMD and microlens array as a switchable module for illumination angle scanning in optical diffraction tomography

Mary E. Swartz, Johann K. Eberhart, Shwetadwip Chowdhury, Jeongsoo Kim, Siqi Yang
article en
14 citations

Abstract

Optical diffraction tomography (ODT) enables label-free and morphological 3D imaging of biological samples using refractive-index (RI) contrast. To accomplish this, ODT systems typically capture multiple angular-specific scattering measurements, which are used to computationally reconstruct a sample's 3D RI. Standard ODT systems employ scanning mirrors to generate angular illuminations. However, scanning mirrors are limited to illuminating the sample from only one angle at a time. Furthermore, when operated at high speeds, these mirrors may exhibit mechanical instabilities that compromise image quality and measurement speed. Recently, newer ODT systems have been introduced that utilize digital-micromirror devices (DMD), spatial light modulators (SLMs), or LED arrays to achieve switchable angle-scanning with no physically-scanning components. However, these systems associate with power inefficiencies and/or spurious diffraction orders that can also limit imaging performance. In this work, we developed a novel non-interferometric ODT system that utilizes a fully switchable module for angle scanning composed of a DMD and microlens array (MLA). Compared to other switchable ODT systems, this module enables each illumination angle to be generated fully independently from every other illumination angle (i.e., no spurious diffraction orders) while also optimizing the power efficiency based on the required density of illumination angles. We validate the quantitative imaging capability of this system using calibration microspheres. We also demonstrate its capability for imaging multiple-scattering samples by imaging an early-stage zebrafish embryo.

Biomedical Optics ExpressVol. 15(10)
The University of Texas at Austin (US)
University of Texas at Austin, Chan Zuckerberg Initiative, National Institutes of Health, Cockrell School of Engineering, University of Texas at Austin
Affordable and clean energy
Openalex Percentile: Top 4%
Digital Holography and Microscopy
4.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.