Energy resolution improvement in simplified alpha spectroscopy for radionuclidic purity tests on 225Ac production floors

This study investigated the feasibility of a simplified method of alpha spectroscopy for radionuclidic purity tests at 225Ac production sites that eliminates the need for a vacuum chamber. The impact of enhancing the energy resolution using a collimator was evaluated through radiation transport simulations. The results showed that a full width at tenth maximum (FWTM) of <300 keV was achieved for alpha particles from 241Am, for which the main energy peak was 5.5 MeV. Experimental validation using an electrodeposition source containing 237Np, 241Am, and 244Cm confirmed an FWTM of 272 keV for both 241Am and 244Cm. These two peaks, with a difference of ~300 keV, were effectively separated. In response to the growing demand for targeted radioisotope therapy, this simplified alpha spectroscopy method offers the potential to detect 226Ra mixed with 225Ac generated by accelerators, given the alpha energy difference of ~700 keV.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-09-01
DOI
https://doi.org/10.1093/rpd/ncae185
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy resolution improvement in simplified alpha spectroscopy for radionuclidic purity tests on 225Ac production floors

Masahiro Fukushi, Osamu Kurihara, Jun Ichinose, Kotaro Tani et al.
1 citations
Radiation Protection Dosimetry
Radiation Detection and Scintillator Technologies
0.61
article

Energy resolution improvement in simplified alpha spectroscopy for radionuclidic purity tests on 225Ac production floors

Masahiro Fukushi, Osamu Kurihara, Jun Ichinose, Kotaro Tani, Kazumasa Inoue, Yuma Mihei, Kotaro Nagatsu
article en
1 citations

Abstract

This study investigated the feasibility of a simplified method of alpha spectroscopy for radionuclidic purity tests at 225Ac production sites that eliminates the need for a vacuum chamber. The impact of enhancing the energy resolution using a collimator was evaluated through radiation transport simulations. The results showed that a full width at tenth maximum (FWTM) of <300 keV was achieved for alpha particles from 241Am, for which the main energy peak was 5.5 MeV. Experimental validation using an electrodeposition source containing 237Np, 241Am, and 244Cm confirmed an FWTM of 272 keV for both 241Am and 244Cm. These two peaks, with a difference of ~300 keV, were effectively separated. In response to the growing demand for targeted radioisotope therapy, this simplified alpha spectroscopy method offers the potential to detect 226Ra mixed with 225Ac generated by accelerators, given the alpha energy difference of ~700 keV.

Radiation Protection DosimetryVol. 200(15)
National Institutes for Quantum Science and Technology (JP), Tokyo Metropolitan University (JP), Tsukuba International University (JP)
Japan Science and Technology Agency
Affordable and clean energy
Openalex Percentile: Top 32%
Radiation Detection and Scintillator Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Energy resolution improvement in simplified alpha spectroscopy for radionuclidic purity tests on 225Ac production floors — Masahiro Fukushi, Osamu Kurihara, et al. · Radiation Protection Dosimetry (2024) | TGRS Research Map | TGRS