Comparing the Rate of Dissolution of Two Commercially Available Synthetic Bone Graft Substitutes

This study characterized the dissolution properties of two commercially available bone substitutes: (1) A calcium sulfate (CaS)/brushite/β-tricalcium phosphate (TCP) graft containing 75% CaS and 25% calcium phosphate; and (2) a CaS/hydroxyapatite (HA) bone graft substitute composed of 60% CaS and 40% HA. Graft material was cast into pellets (4.8 mm outer diameter × 3.2 mm). Each pellet was placed into a fritted thimble and weighed before being placed into 200 mL of deionized water. The pellets were removed from the water on days 1, 2, 3, 4, 6, 8, 14, 18, or until no longer visible. The mass and volume of each pellet were calculated at each timepoint to determine the rate of dissolution. Analysis of variance was performed on all data. Statistical significance was defined as <i>p</i> < 0.05. The CaS/HA pellets were completely dissolved after day 8, while the CaS/brushite/β-TCP pellets remained until day 18. The CaS/brushite/β-TCP pellets had significantly more mass and volume at days 1, 2, 3, 4, 6, and 8 timepoints. The CaS/brushite/β-TCP pellets lost 46% less mass and 53% less volume over the first 4 days as compared to CaS/HA pellets. The CaS/brushite/β-TCP pellets had a rough, porous texture, while the CaS/HA pellets had a smooth outer surface. Overall the CaS/brushite/β-TCP pellets dissolved approximately twice as slowly as the CaS/HA pellets in vitro. As these in vitro findings might have in vivo implications, further clinical data are required to further confirm and establish the optimal synthetic bone substitute strategy or antibiotic delivery carrier.

Authors

Institutions

Publication Details

Journal
The Journal of Knee Surgery
Published
2024-09-05
DOI
https://doi.org/10.1055/a-2410-2552
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing the Rate of Dissolution of Two Commercially Available Synthetic Bone Graft Substitutes

Ignacio Pasqualini, Kara McConaghy, Pedro J. Rullán, Nicolas Santiago Piuzzi et al.
The Journal of Knee Surgery
Bone Tissue Engineering Materials
article

Comparing the Rate of Dissolution of Two Commercially Available Synthetic Bone Graft Substitutes

Ignacio Pasqualini, Kara McConaghy, Pedro J. Rullán, Nicolas Santiago Piuzzi, Mike Smietana, Jesse Fleming
article en

Abstract

This study characterized the dissolution properties of two commercially available bone substitutes: (1) A calcium sulfate (CaS)/brushite/β-tricalcium phosphate (TCP) graft containing 75% CaS and 25% calcium phosphate; and (2) a CaS/hydroxyapatite (HA) bone graft substitute composed of 60% CaS and 40% HA. Graft material was cast into pellets (4.8 mm outer diameter × 3.2 mm). Each pellet was placed into a fritted thimble and weighed before being placed into 200 mL of deionized water. The pellets were removed from the water on days 1, 2, 3, 4, 6, 8, 14, 18, or until no longer visible. The mass and volume of each pellet were calculated at each timepoint to determine the rate of dissolution. Analysis of variance was performed on all data. Statistical significance was defined as <i>p</i> < 0.05. The CaS/HA pellets were completely dissolved after day 8, while the CaS/brushite/β-TCP pellets remained until day 18. The CaS/brushite/β-TCP pellets had significantly more mass and volume at days 1, 2, 3, 4, 6, and 8 timepoints. The CaS/brushite/β-TCP pellets lost 46% less mass and 53% less volume over the first 4 days as compared to CaS/HA pellets. The CaS/brushite/β-TCP pellets had a rough, porous texture, while the CaS/HA pellets had a smooth outer surface. Overall the CaS/brushite/β-TCP pellets dissolved approximately twice as slowly as the CaS/HA pellets in vitro. As these in vitro findings might have in vivo implications, further clinical data are required to further confirm and establish the optimal synthetic bone substitute strategy or antibiotic delivery carrier.

The Journal of Knee SurgeryVol. 38(02)
Cleveland Clinic (US), Cleveland Clinic Lerner College of Medicine (US), University School (US), Stryker (United States) (US), Case Western Reserve University (US)
Clean water and sanitation
Openalex Percentile: Top 87%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.