O21 Safety of intracranial aneurysm treatment by robotically assisted flow diverter implantation

<h3>Introduction</h3> Intraprocedural intracranial aneurysm rupture is one of the most critical possible complications during endovascular treatment. <h3>Aim of Study</h3> The aim of this study was to evaluate the risk of intracranial aneurysm rupture during robotically assisted flow diverter implantation, using the CorPath GRX robotic system. <h3>Methods</h3> From February 1, 2022 to March 20, 2024, 65 target aneurysms (45 saccular) were treated by robotically assisted flow diverter implantation. The most common location of the target aneurysm was ICA (33), followed by AComA (17), MCA (8), ACA (1), AChoA (1), basilar artery (2), PCA (2), and VA (1). <h3>Results</h3> Only one (1.5%) intraprocedural aneurysm rupture was recorded, without the need for manual conversion. Aneurysm rupture was detected on angiogram after microcatheter navigation through aneurysm sac, before flow diverter implantation. No signs of continuous extravasation were visible after the implantation of the flow diverter. The patient recovered completely. <h3>Conclusion</h3> The risk of intraprocedural intracranial aneurysm rupture during robotically assisted flow diverter implantation is low. The results of this study confirmed an acceptable risk of robotically assisted procedures.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.21
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O21 Safety of intracranial aneurysm treatment by robotically assisted flow diverter implantation

Jakub Soršák, Adam Krkoška, Martin Vorčák, Kamil Zeleňák et al.
Abstracts
Intracranial Aneurysms: Treatment and Complications
article

O21 Safety of intracranial aneurysm treatment by robotically assisted flow diverter implantation

Jakub Soršák, Adam Krkoška, Martin Vorčák, Kamil Zeleňák, Ján Sýkora
article en

Abstract

<h3>Introduction</h3> Intraprocedural intracranial aneurysm rupture is one of the most critical possible complications during endovascular treatment. <h3>Aim of Study</h3> The aim of this study was to evaluate the risk of intracranial aneurysm rupture during robotically assisted flow diverter implantation, using the CorPath GRX robotic system. <h3>Methods</h3> From February 1, 2022 to March 20, 2024, 65 target aneurysms (45 saccular) were treated by robotically assisted flow diverter implantation. The most common location of the target aneurysm was ICA (33), followed by AComA (17), MCA (8), ACA (1), AChoA (1), basilar artery (2), PCA (2), and VA (1). <h3>Results</h3> Only one (1.5%) intraprocedural aneurysm rupture was recorded, without the need for manual conversion. Aneurysm rupture was detected on angiogram after microcatheter navigation through aneurysm sac, before flow diverter implantation. No signs of continuous extravasation were visible after the implantation of the flow diverter. The patient recovered completely. <h3>Conclusion</h3> The risk of intraprocedural intracranial aneurysm rupture during robotically assisted flow diverter implantation is low. The results of this study confirmed an acceptable risk of robotically assisted procedures.

Abstracts
Comenius University Bratislava (SK)
Good health and well-being
Openalex Percentile: Top 77%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

O21 Safety of intracranial aneurysm treatment by robotically assisted flow diverter implantation — Jakub Soršák, Adam Krkoška, et al. · Abstracts (2024) | TGRS Research Map | TGRS