<h3>Introduction</h3> The possibility of applying a CT scan during the operation enables the surgeon to control the positioning of the implants. The postoperative control of the implants with the photon counting technology gives the opportunity for a very precise imaging. These two techniques deliver a quite different dose to the patient. <h3>Aim of Study</h3> With this abstract, we would be able to see the relation between the doses of these two techniques in the same patient <h3>Methods</h3> Comparing the dose reports of the same patient with these two different CTs, first in the Angio suite and the second as post-OP. Comparing the image quality of these methods. <h3>Results</h3> The results of the imaging of neuro-endovascular implants are from both techniques reliable. The PCCT-angiography has a higher radiation dose but is also beneficial to monitor treatment success. <h3>Conclusion</h3> The CT in the Angio suite gives an immediate and accurate first impression of the surgery, despite of the lower dose. <h3>Disclosure of Interest</h3> no.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.192
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P157 Dose comparison of CT in angio suite and CT photon – counting

Niki Papadopoulou, Tilman B. Schubert, Zsolt Kulcsár
Abstracts
Advanced X-ray and CT Imaging
article

P157 Dose comparison of CT in angio suite and CT photon – counting

Niki Papadopoulou, Tilman B. Schubert, Zsolt Kulcsár
article en

Abstract

<h3>Introduction</h3> The possibility of applying a CT scan during the operation enables the surgeon to control the positioning of the implants. The postoperative control of the implants with the photon counting technology gives the opportunity for a very precise imaging. These two techniques deliver a quite different dose to the patient. <h3>Aim of Study</h3> With this abstract, we would be able to see the relation between the doses of these two techniques in the same patient <h3>Methods</h3> Comparing the dose reports of the same patient with these two different CTs, first in the Angio suite and the second as post-OP. Comparing the image quality of these methods. <h3>Results</h3> The results of the imaging of neuro-endovascular implants are from both techniques reliable. The PCCT-angiography has a higher radiation dose but is also beneficial to monitor treatment success. <h3>Conclusion</h3> The CT in the Angio suite gives an immediate and accurate first impression of the surgery, despite of the lower dose. <h3>Disclosure of Interest</h3> no.

Abstracts
Laboratory for Social and Neural Systems Research (CH)
Zero hunger
Openalex Percentile: Top 87%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.