P021 Super large bore 0.088 inch HiPoint catheter extender and Tenzing 8 delivery catheter for the treatment of ICA terminus and M1 occlusions

<h3>Introduction</h3> Super large-bore catheters (SLBC) with a 0.088’ distal ID may generate greater aspiration force but deliverability is more challenging. The Tenzing 8 (Route 92 Medical, San Mateo, CA) shelf-reducing delivery catheter is designed to permit tracking of HiPoint 088 (Route 92 Medical, San Mateo, CA), a SLBC-extender. <h3>Aim of Study</h3> We report our initial experience with this system in the treatment of ICA terminus and M1 occlusions. <h3>Methods</h3> Using prospectively maintained institutional databases, we retrospectively reviewed clinical and angiographic data of consecutive patients who underwent off-label aspiration thrombectomy (AT) with Tenzing 8 and HiPoint 088 between 2021-2024. <h3>Results</h3> Seventy patients underwent AT with Tenzing 8/HiPoint 088 catheters: 51% female; median age 72(IQR 62-80) years; median baseline NIHSS 19(IQR 14-24); 22 ICA terminus and 48 M1 MCA occlusions. HiPoint 088 was successfully delivered to the target occlusion in 66/70(94%). A leading microwire was not needed to advance the system to the occlusion in 71%. Adjunctive thrombectomy devices were used for secondary/distal occlusions in 21%. The rate of successful revascularization (mTICI ≥ 2b) was 99%. First pass effect mTICI ≥ 2C for M1 occlusions was 65%. Median number of passes was 1 (IQR 1-2); median groin puncture to first pass time was 13(IQR 8-19) minutes with median revascularization time of 21(IQR 16-34) minutes. There were 6 procedural complications (1 cervical ICA dissection, 4 femoral artery occlusions, 1 SAH related to adjunctive device use) and 2 sICH. <h3>Conclusion</h3> High catheter delivery and reperfusion rates were achieved using Tenzing 8 and HiPoint 088, with a low complication rate. <h3>Disclosure of Interest</h3> yes Fabio Settecase, Warren Kim, Joey English: Consultant and Equity interest in Route 92 Medical. Blaise Baxter: Consultant for Stryker, Medical Device Business Services, Inc.; Honoraria: Penumbra.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.58
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P021 Super large bore 0.088 inch HiPoint catheter extender and Tenzing 8 delivery catheter for the treatment of ICA terminus and M1 occlusions

Matthew D. Alexander, Fabio Settecase, Joey English, Nobl Barazangi et al.
Abstracts
Peripheral Artery Disease Management
article

P021 Super large bore 0.088 inch HiPoint catheter extender and Tenzing 8 delivery catheter for the treatment of ICA terminus and M1 occlusions

Matthew D. Alexander, Fabio Settecase, Joey English, Nobl Barazangi, Jaehyun Kim, Warren Kim, Blaise Baxter
article en

Abstract

<h3>Introduction</h3> Super large-bore catheters (SLBC) with a 0.088’ distal ID may generate greater aspiration force but deliverability is more challenging. The Tenzing 8 (Route 92 Medical, San Mateo, CA) shelf-reducing delivery catheter is designed to permit tracking of HiPoint 088 (Route 92 Medical, San Mateo, CA), a SLBC-extender. <h3>Aim of Study</h3> We report our initial experience with this system in the treatment of ICA terminus and M1 occlusions. <h3>Methods</h3> Using prospectively maintained institutional databases, we retrospectively reviewed clinical and angiographic data of consecutive patients who underwent off-label aspiration thrombectomy (AT) with Tenzing 8 and HiPoint 088 between 2021-2024. <h3>Results</h3> Seventy patients underwent AT with Tenzing 8/HiPoint 088 catheters: 51% female; median age 72(IQR 62-80) years; median baseline NIHSS 19(IQR 14-24); 22 ICA terminus and 48 M1 MCA occlusions. HiPoint 088 was successfully delivered to the target occlusion in 66/70(94%). A leading microwire was not needed to advance the system to the occlusion in 71%. Adjunctive thrombectomy devices were used for secondary/distal occlusions in 21%. The rate of successful revascularization (mTICI ≥ 2b) was 99%. First pass effect mTICI ≥ 2C for M1 occlusions was 65%. Median number of passes was 1 (IQR 1-2); median groin puncture to first pass time was 13(IQR 8-19) minutes with median revascularization time of 21(IQR 16-34) minutes. There were 6 procedural complications (1 cervical ICA dissection, 4 femoral artery occlusions, 1 SAH related to adjunctive device use) and 2 sICH. <h3>Conclusion</h3> High catheter delivery and reperfusion rates were achieved using Tenzing 8 and HiPoint 088, with a low complication rate. <h3>Disclosure of Interest</h3> yes Fabio Settecase, Warren Kim, Joey English: Consultant and Equity interest in Route 92 Medical. Blaise Baxter: Consultant for Stryker, Medical Device Business Services, Inc.; Honoraria: Penumbra.

Abstracts
Sutter Medical Center (US), California Pacific Medical Center (US), Mills Peninsula Health Services (US)
Openalex Percentile: Top 73%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.