P016 Simulating extra- and intracranial stenosis in a 3D-printed neurovascular model

<h3>Introduction</h3> Atherosclerotic disease has been described as an important underlying etiology of refractory occlusions. Despite being challenging thrombectomy procedures for interventionalists, clinically accurate simulation flow models have not yet been developed. <h3>Aim of Study</h3> To develop and test a 3D-printed stenosis model for research and training purposes. <h3>Methods</h3> Stereolithography 3D-printing was used to create an elastic neurovascular model based on vascular anatomies extracted from anonymized CTA images. The phantom includes the aortic arch, bilateral carotid arteries, and a complete circle of Willis up to the M2-MCA, A2-ACA, and P2-PCA segments. To produce the stenotic segments, 3% sodium alginate solution was cast into stenosis molds featuring different geometries and then crosslinked in a 40% calcium chloride solution. <h3>Results</h3> An 80% MCA-M1 stenosis (8mm-long segment with a luminal diameter of 0.5mm) and a 90% ICA stenosis (30mm-long segment with a luminal diameter of 0.7mm) were successfully implemented in the neurovascular flow model. The neurointerventionalist performing the simulation of the procedure deemed the angioplasty as intricate, consistent with the complexity often associated with severe stenosis. Angioplasties performed without a protection device resulted in visible emboli collected in a filter placed in the outflow of the model. Figure 1 and 2 represent intracranial and extracranial stenosis, respectively, with their corresponding postprocessed filter image after angioplasty treatment. Emboli parameters are included in both figures. <h3>Conclusion</h3> A workflow for stenosis implementation inside a clinically accurate 3D model has been proposed as the first step toward educating future neurointerventionalists on performing endovascular treatment in severe stenosis. <h3>Disclosure of Interest</h3> no.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.53
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P016 Simulating extra- and intracranial stenosis in a 3D-printed neurovascular model

Pere Canals, Riccardo Tiberi, Alejandro Tomasello, Marc Ribó et al.
Abstracts
Anatomy and Medical Technology
article

P016 Simulating extra- and intracranial stenosis in a 3D-printed neurovascular model

Pere Canals, Riccardo Tiberi, Alejandro Tomasello, Marc Ribó, Judith Cendrero, Jiahui Li, Marc Molina Van den Bosch, Magda Jablonska, Joan Daniel Vargas
article en

Abstract

<h3>Introduction</h3> Atherosclerotic disease has been described as an important underlying etiology of refractory occlusions. Despite being challenging thrombectomy procedures for interventionalists, clinically accurate simulation flow models have not yet been developed. <h3>Aim of Study</h3> To develop and test a 3D-printed stenosis model for research and training purposes. <h3>Methods</h3> Stereolithography 3D-printing was used to create an elastic neurovascular model based on vascular anatomies extracted from anonymized CTA images. The phantom includes the aortic arch, bilateral carotid arteries, and a complete circle of Willis up to the M2-MCA, A2-ACA, and P2-PCA segments. To produce the stenotic segments, 3% sodium alginate solution was cast into stenosis molds featuring different geometries and then crosslinked in a 40% calcium chloride solution. <h3>Results</h3> An 80% MCA-M1 stenosis (8mm-long segment with a luminal diameter of 0.5mm) and a 90% ICA stenosis (30mm-long segment with a luminal diameter of 0.7mm) were successfully implemented in the neurovascular flow model. The neurointerventionalist performing the simulation of the procedure deemed the angioplasty as intricate, consistent with the complexity often associated with severe stenosis. Angioplasties performed without a protection device resulted in visible emboli collected in a filter placed in the outflow of the model. Figure 1 and 2 represent intracranial and extracranial stenosis, respectively, with their corresponding postprocessed filter image after angioplasty treatment. Emboli parameters are included in both figures. <h3>Conclusion</h3> A workflow for stenosis implementation inside a clinically accurate 3D model has been proposed as the first step toward educating future neurointerventionalists on performing endovascular treatment in severe stenosis. <h3>Disclosure of Interest</h3> no.

Abstracts
Vall d'Hebron Institut de Recerca (ES)
Openalex Percentile: Top 87%
Anatomy and Medical Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.