P046 Venous sinus stenting with HiPoint 088 catheter extender and Tenzing 8

<h3>Introduction</h3> Stenting is increasingly performed for venous sinus stenosis associated with refractory pseudotumor cerebri and pulsatile tinnitus (PT). The Monopoint access system (Route 92 Medical, San Mateo,CA) is a triaxial telescoping system of catheters with simplified points of control outside the body, consisting of: 0.106’ Base Camp guide cather, 0.088 inch ID catheter on a wire (HiPoint 88) and delivery catheter (Tenzing 8). The system may be well suited to venous sinus stenting(VSS). <h3>Case Description</h3> A female in her mid-40s presented with pressure headaches, visual obscurations, papilledema with field cut, and PT. MRI revealed bilateral traverse sinus stenoses. Attempted medical therapies (Diamox, weight loss) had failed to improve her condition. DSA showed a dominant right transverse sinus stenosis with a 15 mmHg pressure gradient. VSS was performed. After 9 F femoral venous access, a Basecamp was placed in the right jugular bulb. The right transverse sinus stenosis was crossed, first with a leading 0.014 inch microwire with a ‘J’ shaped tip, followed by Tenzing 8, followed by HiPoint 88, without difficulty. After Tenzing removal, a Zilver 518 8 x 40 mm stent (Cook,Bloomington,IN) was advanced to the target within the HiPoint 88 (figure 1A) and unsheathed by pulling back the HiPoint wire (figure 1B, black arrow). The stent was deployed. No residual stenosis or complications were observed. She was discharged on a 6-months of dual antiplatelets. <h3>Results</h3> At 8 month clinical follow up, her headaches, vision, papilledema and PT had improved, with wide stent patency on MRI head. <h3>Disclosure of Interest</h3> yes Fabio Settecase: consultant and equity interest Route 92 Medical.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.83
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P046 Venous sinus stenting with HiPoint 088 catheter extender and Tenzing 8

Fabio Settecase
Abstracts
Venous Thromboembolism Diagnosis and Management
article

P046 Venous sinus stenting with HiPoint 088 catheter extender and Tenzing 8

Fabio Settecase
article en

Abstract

<h3>Introduction</h3> Stenting is increasingly performed for venous sinus stenosis associated with refractory pseudotumor cerebri and pulsatile tinnitus (PT). The Monopoint access system (Route 92 Medical, San Mateo,CA) is a triaxial telescoping system of catheters with simplified points of control outside the body, consisting of: 0.106’ Base Camp guide cather, 0.088 inch ID catheter on a wire (HiPoint 88) and delivery catheter (Tenzing 8). The system may be well suited to venous sinus stenting(VSS). <h3>Case Description</h3> A female in her mid-40s presented with pressure headaches, visual obscurations, papilledema with field cut, and PT. MRI revealed bilateral traverse sinus stenoses. Attempted medical therapies (Diamox, weight loss) had failed to improve her condition. DSA showed a dominant right transverse sinus stenosis with a 15 mmHg pressure gradient. VSS was performed. After 9 F femoral venous access, a Basecamp was placed in the right jugular bulb. The right transverse sinus stenosis was crossed, first with a leading 0.014 inch microwire with a ‘J’ shaped tip, followed by Tenzing 8, followed by HiPoint 88, without difficulty. After Tenzing removal, a Zilver 518 8 x 40 mm stent (Cook,Bloomington,IN) was advanced to the target within the HiPoint 88 (figure 1A) and unsheathed by pulling back the HiPoint wire (figure 1B, black arrow). The stent was deployed. No residual stenosis or complications were observed. She was discharged on a 6-months of dual antiplatelets. <h3>Results</h3> At 8 month clinical follow up, her headaches, vision, papilledema and PT had improved, with wide stent patency on MRI head. <h3>Disclosure of Interest</h3> yes Fabio Settecase: consultant and equity interest Route 92 Medical.

Abstracts
California Pacific Medical Center (US)
Openalex Percentile: Top 71%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

P046 Venous sinus stenting with HiPoint 088 catheter extender and Tenzing 8 — Fabio Settecase · Abstracts (2024) | TGRS Research Map | TGRS