O06 Combined MIVI-Q aspiration catheter-stent retriever approach to primary medium vessel occlusions stroke thrombectomy: preliminary clinical experience

<h3>Introduction</h3> Emerging data suggests the safety and effectiveness of EVT for primary medium vessel occlusions (pMeVOs) like distal M2 and the M3 segments as well as the ACA and PCA, in part due to the improvement of stent-retriever (SR), aspiration catheters and endovascular techniques. <h3>Aim of Study</h3> We assessed the efficacy and safety of the novel MIVI Q<sup>TM</sup> aspiration catheters in combination with SR devices in the treatment of pMeVOs. <h3>Methods</h3> We retrospectively analyzed demographics, procedure characteristics, and clinical data from consecutive patients with acute pMeVOs treated with a combined approach using MIVI Q<sup>TM</sup> aspiration catheters and SR. Reperfusion was defined according to the Modified Thrombosis in Cerebral Infarction (mTICI) score. Clinical outcomes were measured by the National Institute of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores. <h3>Results</h3> We included 40 patients [median age, 74 y (IQR:62-80); 24 (60%) male; 34 (85%) with occlusion in the M2/M3 segment of the MCA, 5 (12.5%) in the PCA, and 1 (2.5%) in the ACA; median NIHSS score at admission was 12.5 (IQR:9.25-18)]. After the first pass, 19 (47.5%) patients had mTICI≥2c. At the end of the procedure, 39 (97.5%) had mTICI≥2b and 31 (77.5%) had mTICI≥2c. No serious device-related adverse events were observed. Symptomatic intracranial hemorrhage developed in 4 (10%) patients. At 90 days, 21 (52.5%) patients were functionally independent (mRS 0-2). <h3>Conclusion</h3> This preliminary study found good efficacy and safety for MIVI Q<sup>TM</sup> aspiration catheters used in combination with SR devices in the treatment of pMeVOs. <h3>Disclosure of Interest</h3> no.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.6
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O06 Combined MIVI-Q aspiration catheter-stent retriever approach to primary medium vessel occlusions stroke thrombectomy: preliminary clinical experience

Mariano Werner, Carlos Castaño, Josep Puig Alcántara, Mikel Terceño et al.
Abstracts
Acute Ischemic Stroke Management
article

O06 Combined MIVI-Q aspiration catheter-stent retriever approach to primary medium vessel occlusions stroke thrombectomy: preliminary clinical experience

Mariano Werner, Carlos Castaño, Josep Puig Alcántara, Mikel Terceño, Saima Bashir, Isabel Rodríguez Caamaño, Sebastià Remollo
article en

Abstract

<h3>Introduction</h3> Emerging data suggests the safety and effectiveness of EVT for primary medium vessel occlusions (pMeVOs) like distal M2 and the M3 segments as well as the ACA and PCA, in part due to the improvement of stent-retriever (SR), aspiration catheters and endovascular techniques. <h3>Aim of Study</h3> We assessed the efficacy and safety of the novel MIVI Q<sup>TM</sup> aspiration catheters in combination with SR devices in the treatment of pMeVOs. <h3>Methods</h3> We retrospectively analyzed demographics, procedure characteristics, and clinical data from consecutive patients with acute pMeVOs treated with a combined approach using MIVI Q<sup>TM</sup> aspiration catheters and SR. Reperfusion was defined according to the Modified Thrombosis in Cerebral Infarction (mTICI) score. Clinical outcomes were measured by the National Institute of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores. <h3>Results</h3> We included 40 patients [median age, 74 y (IQR:62-80); 24 (60%) male; 34 (85%) with occlusion in the M2/M3 segment of the MCA, 5 (12.5%) in the PCA, and 1 (2.5%) in the ACA; median NIHSS score at admission was 12.5 (IQR:9.25-18)]. After the first pass, 19 (47.5%) patients had mTICI≥2c. At the end of the procedure, 39 (97.5%) had mTICI≥2b and 31 (77.5%) had mTICI≥2c. No serious device-related adverse events were observed. Symptomatic intracranial hemorrhage developed in 4 (10%) patients. At 90 days, 21 (52.5%) patients were functionally independent (mRS 0-2). <h3>Conclusion</h3> This preliminary study found good efficacy and safety for MIVI Q<sup>TM</sup> aspiration catheters used in combination with SR devices in the treatment of pMeVOs. <h3>Disclosure of Interest</h3> no.

Abstracts
Hospital Clínic de Barcelona (ES), Hospital Universitari Germans Trias i Pujol (ES), Hospital Universitari de Girona Doctor Josep Trueta (ES)
Openalex Percentile: Top 78%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.