O07 Accelerated aspiration with Q catheter: an in vitro study

<h3>Introduction</h3> Thrombectomy in distal, medium vessels is a topic of increasing interest. To date there are few <i>in vitro</i> studies focused on performance of ≤ 5F catheters in medium vessels <h3>Aim of Study</h3> The purpose of this study is to compare the performance of the 3F, 4F, and 5F MIVI Neuroscience Q Catheters versus Penumbra 3F, 4F, and MicroVention Sofia 5F Catheters. <h3>Methods</h3> Using <i>in vitro</i> methods, we assessed and compared the following parameters: aspiration flow rates, clot uncorking forces, impulse, and clot ingestion. For flow rate, each aspiration catheter was immersed in a cylindrical container. Flow rate at one second was used to calculate impulse. For clot uncorking force, the force required to disengage a catheter from a simulated clot was recorded. For ingestion, we measured time to ingest soft and medium stiffness synthetic clots. <h3>Results</h3> The measured flow rates without a stent retriever for the Q3, Q4 and Q5 catheters were 3.54 ml/s, 5.32 ml/s and 6.87 ml/s. The measured flow rates without a stent retriever for the 3MAX, 4MAX and 5Fr Sofia were 1.46 ml/s, 2.56 ml/s and 1.73 ml/s. The impulse calculated for one second was 26 mNs for Q5 vs 9 mNs for Sofia 5, 35 mNs for Q4 vs 15 mNs for 4Max and 35 mNs for Q3 vs 9 mNs for 3Max. The average system ingestion for Q was significantly faster than the competitive catheters. <h3>Conclusion</h3> The Q catheters demonstrated higher flow rates, higher uncorking force, and faster complete clot ingestion than competitive catheters. <h3>Disclosure of Interest</h3> yes Competing interests: Trent Langston is employees of MIVI Neuroscience. John Wainwright is a former employee of MIVI Neuroscience. Mayra Contreras, Waleed Brinjikji, and Naomi Chesler are consultants for MIVI Neuroscience. Waleed Brinjikji: MIVI Neuroscience, Medtronic, MicroVention, and Balt. Paolo Machi is a consultant for MIVI Neuroscience, Medtronic, Stryker and MicroVention.

Authors

Institutions

Publication Details

Journal
Abstracts
Published
2024-09-01
DOI
https://doi.org/10.1136/jnis-2024-esmint.7
Primary Topic
Urinary Tract Infections Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O07 Accelerated aspiration with Q catheter: an in vitro study

Philippe Reymond, Olivier Brina, Mayra Contreras, Naomi C. Chesler et al.
1 links
Abstracts
Urinary Tract Infections Management
article

O07 Accelerated aspiration with Q catheter: an in vitro study

Philippe Reymond, Olivier Brina, Mayra Contreras, Naomi C. Chesler, Waleed Brinjikji, Paolo Machi, J Wainwright, Trent Langston
article en

Abstract

<h3>Introduction</h3> Thrombectomy in distal, medium vessels is a topic of increasing interest. To date there are few <i>in vitro</i> studies focused on performance of ≤ 5F catheters in medium vessels <h3>Aim of Study</h3> The purpose of this study is to compare the performance of the 3F, 4F, and 5F MIVI Neuroscience Q Catheters versus Penumbra 3F, 4F, and MicroVention Sofia 5F Catheters. <h3>Methods</h3> Using <i>in vitro</i> methods, we assessed and compared the following parameters: aspiration flow rates, clot uncorking forces, impulse, and clot ingestion. For flow rate, each aspiration catheter was immersed in a cylindrical container. Flow rate at one second was used to calculate impulse. For clot uncorking force, the force required to disengage a catheter from a simulated clot was recorded. For ingestion, we measured time to ingest soft and medium stiffness synthetic clots. <h3>Results</h3> The measured flow rates without a stent retriever for the Q3, Q4 and Q5 catheters were 3.54 ml/s, 5.32 ml/s and 6.87 ml/s. The measured flow rates without a stent retriever for the 3MAX, 4MAX and 5Fr Sofia were 1.46 ml/s, 2.56 ml/s and 1.73 ml/s. The impulse calculated for one second was 26 mNs for Q5 vs 9 mNs for Sofia 5, 35 mNs for Q4 vs 15 mNs for 4Max and 35 mNs for Q3 vs 9 mNs for 3Max. The average system ingestion for Q was significantly faster than the competitive catheters. <h3>Conclusion</h3> The Q catheters demonstrated higher flow rates, higher uncorking force, and faster complete clot ingestion than competitive catheters. <h3>Disclosure of Interest</h3> yes Competing interests: Trent Langston is employees of MIVI Neuroscience. John Wainwright is a former employee of MIVI Neuroscience. Mayra Contreras, Waleed Brinjikji, and Naomi Chesler are consultants for MIVI Neuroscience. Waleed Brinjikji: MIVI Neuroscience, Medtronic, MicroVention, and Balt. Paolo Machi is a consultant for MIVI Neuroscience, Medtronic, Stryker and MicroVention.

Abstracts
Mayo Clinic (US), University of California, Irvine (US), WinnMed (US), University Hospital of Geneva (CH), Optum (United States) (US), Samueli Institute (US), Irvine University (US)
Zero hunger
Openalex Percentile: Top 78%
Urinary Tract Infections Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.